Disc valve for supply air / extract air (please select) Steel, powder-coated, white RAL 9010 The volume flow can be infinitely adjusted using the adjustable disc Mounting ring / installation frame included Large adjustment range Low noise level Quick and easy to install The designer disc valve is made of powder-coated sheet steel. The standard colour is white (RAL 9010). A good seal is achieved by combining the valve body with a spring catch (bayonet catch) and sealing tape. The disc valve has an adjustable, centrally arranged, rotating valve disc. It has a low noise level. Exhaust air valve: Designed for exhaust air operation in residential buildings and offices as well as for toilet ventilation. Supply air valve: Designed for supply air operation in homes and offices. Areas of application: Spiral duct connection Residential buildings Offices restaurants kitchen
Planungspaket: Luft/Luft-Wärmerückgewinnungsanlage Leistungsumfang: Dieses Planungspaket umfasst alle wesentlichen Schritte für die professionelle Auslegung Ihrer Lüftungsanlage: Festlegung der Volumenströme auf Basis der Gebäudedaten und Raumnutzung Dimensionierung des Leitungsnetzes inklusive Berechnung der erforderlichen Luftgeschwindigkeiten Auslegung der Schalldämmmaßnahmen zur Gewährleistung eines leisen Anlagenbetriebs Zeichnerische Darstellung der Anlage mit CAD in den Grundrissen Ihres Gebäudes Schematische Darstellung der Luftführung mit Positionen der Zu- und Abluftkomponenten Material- und Stückliste aller benötigten Komponenten Installationshinweise für eine fachgerechte Umsetzung Planungsunterlage als PDF-Datei, vollständig dokumentiert und projektbezogen Das Ergebnis ist eine vollständige technische Grundlage zur Umsetzung Ihrer kontrollierten Wohnraumlüftung mit Wärmerückgewinnung. Was brauchen wir von Ihnen? • Gebäudegrundrisse, Schnitte als PDF-Datei (oder auch DWG I DXF). • Nutzungsbezeichnung der Räume mit Flächenberechnung. • Hinweise zu Installationsmöglichkeiten (Technikraum , abgehängte Decke, Wandaufbau, Installationsschacht etc.). • Evtl. Pläne mit Einskizzierung Ihrer Vorstellung zum Leitungsverlauf. • Nennen Sie uns einen Ansprechpartner für die Abstimmung zur Ausarbeitung.
Socket made of galvanised sheet steel for connecting individual parts of the plastic ventilation duct Ø 63 mm.
Weather protection grille Ø 100 mm to Ø 200 mm type WSKED Stainless steel V2A Design weather protection grille for outside, weatherproof With bird protection grille mesh size 12.5 x 12.5 mm With rigid slats The clamping tab prevents watermarks on the wall With rubber sealing tape for perfect connection to the external façade, screws for installation included in the scope of delivery Round connection on the back for connecting a ventilation pipe or hose Installation:Attach the rubber seal to the outer edge of the bonnet. This sometimes requires a little patience. Also attach the clamping tab. Then insert the weather protection grille with the connection piece into the ventilation duct and fix it directly to the wall using the screws provided. For better fastening in the ventilation duct, there are clamping lugs on the spigot of the bonnet.
Distribution box, 1x DN200 nipple inlet with lip seal, 6x DN63 outlets, 3 outlets per long side, galvanised Width: 300mm; Height: 145mm; Length: 600mm
EPDM sealing ring 63 mm, suitable for the XS system 63 mm
Discharge elbow nominal width 100 mm to 300 mm H = 1150 mm made of stainless steel V2A 1.4301 (ground grain 200) with bird protection grille Only suitable for KG pipe (orange) Discharge elbow in 135° segment design Pipe connection with EPDM double lip seal for connection to KG pipeIs pushed into KG pipe, with lip seal
Distribution box with two DN200 connections and 12 DN75 outlets Made of galvanised sheet steel 6 outlets per side as general distributor Width: 235mm; Height: 305mm; Depth: 235mm Inlet: 2x DN200 ; Outlet: 12x DN75
Distribution box, 1x DN200 nipple inlet with lip seal, 18x DN63 outlets, 9 outlets per long side, galvanised Width: 300mm; Height: 145mm; Length: 600mm
Ventilation pipe for use as a supply or exhaust air pipe in rooms with centralised systems for controlled domestic ventilation. Outer diameter 63 mm Inner diameter 51 mm Flexible ventilation pipe in composite pipe construction Corrugated outside, smooth inside Hygienically tested Outer pipe pressure-resistant, inner pipe sound-absorbing
Distribution box, 1x DN250 inlet nipple with lip seal, 12x DN63 outlet, 2 rows of 6 on one side, galvanised Width: 560mm; Height: 500mm; Depth: 300mm
Distribution box, 1x DN250 inlet nipple with lip seal, 6x DN63 outlets, 1 row of 6 on one side, galvanised Width: 560mm; Height: 500mm; Depth: 300mm
Ventilation pipe for use as a supply or exhaust air pipe in rooms with centralised systems for controlled domestic ventilation. Outer diameter 75 mm Inner diameter 63 mm Flexible ventilation pipe in composite pipe construction Corrugated outside, smooth inside Hygienically tested Outer pipe pressure-resistant, inner pipe sound-absorbing
Air filter box for duct installation in ventilation systems connections with EPDM lip seal Removable cover for filter change Made of galvanised steel incl. G4 filter
Distribution box, 1x DN200 nipple inlet with lip seal, 12x DN63 outlets, 6 outlets per long side, galvanised Width: 300mm; Height: 145mm; Length: 600mm
Louvre cover round V2A DN 160 in RAL 7004 spray-painted
Telescopic wall conduct 125 mm with double non-return damper, blower door compatible and round flange Plastic round duct 125 mm flange with round connection Ø 125 mm Weather protection grille WSQLE125 2 non-return dampers Telescopic round duct plastic 125 mm, length 300 - 500 mm
Distribution box, 1x DN250 inlet nipple with lip seal, 10x DN63 outlet, 2 rows of 5 on one side, galvanised Width: 560mm; Height: 500mm; Depth: 300mm
Louvre cover round V2A DN 160 in RAL 7031 spray-painted
Branch piece for direct connection of a disc valve Ø 125 mm Connection to the XS system hose via two spigots Ø 75 mm For attachment to the floor, wall or ceiling Auxiliary brackets with holes on the side The shape tapers towards the rear to ensure the best possible air flow Connection: 2x Ø 75 mm; Outlet: Ø 125 mm; Height: 150 mm
LUNOS
Serie ZuluftelementeDer ALD ist ein Außenwand-Luftdurchlass. Außenwand-Luftdurchlässe dienen als passive Nachströmung für Wohn- und Schlafräume. Sie werden vor allem in Kombination mit den Abluftgeräten der Silvento-Reihe genutzt. Durch diese Ablüfter wird ein stetiger Unterdruck gebildet, der über die Außenwand-Luftdurchlässe Frischluft in das Haus transportiert.BesonderheitenDer ALD ist unser Außenwand-Luftdurchlass für alle Anwendungen. Besonders hat es sich für den Einsatz in Wohn- und Schlafräumen bewährt.EinbauDer Einschub wird in den Rundkanal 9/R 160 (ø 160 mm) eingesetzt. Der elektrische Anschluss entfällt, da der ALD ein passives Zuluftelement ist. Die Behaglichkeit in den Wohnräumen hängt in hohem Maße von der Positionierung und Beschaffenheit der Außenwand-Luftdurchlässe ab. Der ALD ist deshalb mit Winddrucksicherung und strömungsgünstiger Blende ausgestattet, um eine zugfreie, diffuse Lufteinströmung zu ermöglichen. Dennoch muss eine sorgfältige Planung der Einbauposition erfolgen. Wird die einströmende Luft möglichst rasch und außerhalb der Aufenthaltszone erwärmt, ist ein Risiko von Zugluft ausgeschlossen. Daher ist eine optimale Anordnung der ALD im Verhältnis zu den Heizflächen notwendig.Wie ein bestehender ALD gegen einen neuen Lüfter mit Wärmerückgewinnung einfach ausgetauscht werden kann, um damit das Gebäude technisch & energetisch aufzuwerten und dabei noch Geld & Energie zu sparen, erklären wir in diesem Video.ExtraUnsere Außenwand-Luftdurchlässe stellen bei normgerechter Planung eine nutzerunabhängige Lüftung nach DIN 1946-6 sicher.Art.-Nr. 39997
Externes Zeitnachlaufmodul 5/ZIIMerkmale:Einbau in Abzweigdosen und 60 mm tiefe Schalterdosen, für programmierbare vollautomatische Nachlaufsteuerung, Einschaltverzögerung, Inversschaltung und wählbare Intervallschaltung.Werkseinstellung 120 Sek. Einschaltverzögerung, 15 Min.Nachlauf, Intervallbetrieb und Inversbetrieb AUSTechnische Daten:Nachlaufzeiten: 6/15 Min.Einschaltverzögerung: 0/120 Sek.Intervallbetrieb: AUS oder alle 4 Std., Laufzeit 30 Min. InversbetriebAbmessungen (HxBxT): 49 x 35 x 10 mmFunktionsspannungsbereich: 180 bis 275 V ACBetriebsschaltstrom: max. 0,5 AAnschlussleistung: max. 115 W
WärmerückgewinnungsgerätDer Nexxt ist ein Wärmerückgewinnungsgerät, welches durch seinen hohen Volumenstrom bestens für den Einsatz in Kindergärten, Schulen, Büros, Hotels, Arztpraxen, aber auch für Wohnung und Haus geeignet ist.BesonderheitenDurch seine sehr geringen Leistungsaufnahmen ist der Nexxt sehr energieeffizient und ermöglicht einen geringen Stromverbrauch. Die integrierte Steuerung sorgt für ein perfektes Zusammenspiel der verschiedenen Komponenten. Ausgestattet mit Feuchte-Temperatur-Sensorik, sorgt die Steuerautomatik schon in der Standardausführung für eine effiziente Lüftung mit Feuchteschutz. Optional kann der Nexxt mit dem FM-EO-Funkmodul zur Steuerung und Kommunikation mit anderen LUNOS-Komponenten und zur Smart Home-Einbindung ausgestattet werden.Der Enthalpie-Wärmetauscher erreicht einen Wärmerückgewinnungsgrad von bis zu 84%. Zusätzlich sorgt die Wirkungsweise des Wärmetauschers für einen weitestgehend vereisungsfreien Betrieb und für Behaglichkeit im Innenraum auch bei kalter Außenluft.Für höchste Ansprüche an die Hygiene sorgen Filter bis Filterklasse F9 oder ePM1 80%.EinbauMontieren Sie das Lüftungsgerät mit einem empfohlenen seitlichen Mindestabstand von 30 cm und einem empfohlenen Mindestabstand nach oben und nach unten von 15 cm. Der seitliche Abstand dient zur Gewährleistung der Lüftungsfunktion, der Abstand nach oben und nach unten der Montagefreiheit. Wir empfehlen, das Gerät in einer Höhe von 1,50 m einzubauen, damit eine nutzerfreundliche Bedienung gewährleistet ist.ExtraAn den Nexxt kann die Diagnosesoftware von LUNOS angeschlossen werden, über deren Vorteile wir hier informieren. Erhältlich mit optionalen elektrischen Klappenverschluss: Öffnet, bzw. schließt die Wanddurchführung beim Ein- oder Ausschalten des Gerätes automatisch.Art.-Nr. 40130
Das Zweitraumset ist ein unverzichtbares Zubehör für die Umrüstung des Einraum-Unterputzgehäuses 3/UP des Silvento ec. Dieses Set ermöglicht eine flexible Anpassung und Erweiterung der Funktionalität des bestehenden Systems, um den individuellen Anforderungen und Wünschen gerecht zu werden.Im Lieferumfang des Zweitraumsets sind mehrere wichtige Komponenten enthalten, die eine einfache und effiziente Installation gewährleisten. Dazu gehören: Der Stutzen, der eine sichere Verbindung zwischen den verschiedenen Elementen des Systems herstellt. Eine spezielle Folie, die für eine optimale Abdichtung sorgt und somit die Effizienz des Systems erhöht. Die Zweitraumblende 2/ZSKA, die nicht nur funktionale Aspekte berücksichtigt, sondern auch ästhetische Gesichtspunkte in den Vordergrund stellt. Diese Blende fügt sich harmonisch in das Gesamtbild des Raumes ein und trägt zu einem ansprechenden Design bei.Zusätzlich wird eine Montagehalterung mitgeliefert, die eine unkomplizierte und stabile Befestigung des Systems ermöglicht. Diese Halterung sorgt dafür, dass alle Komponenten sicher und zuverlässig an ihrem Platz bleiben, was die Langlebigkeit und Funktionalität des gesamten Systems unterstützt.Art.-Nr. 39209
Die Schalldämmelemente sind aus einer speziellen Zusammenstellung von technischen Schäumen gefertigt, die gezielt entwickelt wurden, um eine optimale Schalldämmung zu gewährleisten. Diese Elemente spielen eine entscheidende Rolle in der Schallisolierung von Gebäuden & tragen dazu bei, den Geräuschpegel in Innenräumen signifikant zu reduzieren. Besonders hervorzuheben ist die modulare Eigenschaft des neuen Mehrkomponenten-Schaumstoffes, der die Schalldämmeigenschaften unserer ALD-Modelle optimiert.Durch die Verwendung dieser innovativen Schaumstoffe wird nicht nur die akustische Leistung verbessert, sondern auch die Flexibilität in der Anwendung erhöht. Die verschiedenen Schichten und Materialien des Schaumstoffs ermöglichen eine Anpassung an unterschiedliche Anforderungen und Gegebenheiten, was die Effizienz der Schalldämmung weiter steigert.Zusätzlich zu den akustischen Vorteilen bieten diese Schalldämmelemente auch thermische Isolierungseigenschaften, die zur Energieeffizienz des Gebäudes beitragen. Die Kombination aus Schall- und Wärmedämmung macht diese Elemente zu einer idealen Wahl für moderne Bauprojekte, die sowohl Komfort als auch Nachhaltigkeit in den Vordergrund stellen.Schalldämpfer 9/SD-SFür die Geräte ALD, ALD-SV, RA 15-60 und e²60Schalldämpfer 9/SD-SKFür die Lüfter ALD-S und e²60 Artikel-Nr.9/SD-S 399199/SD-SK 41134
Rundkanal für die 160er-Serie – Vielseitige Anwendung für optimale LuftführungDer Rundkanal ist eine essentielle Komponente für alle Lüftungsgeräte der 160er-Serie, einschließlich den Fassadenelementen LUNOtherm zur Lüftung in der Fensterlaibung. Er sorgt für eine effiziente Luftführung und ist in zwei praktischen Größen erhältlich, um unterschiedlichen Anforderungen gerecht zu werden.Verfügbare Größen:∅ 160 x L 500 mm∅ 160 x L 700 mmEinbauDer Rundkanal 9/R 160 lässt sich unkompliziert installieren. Er wird direkt in die Außenwand oder in das Wandeinbaugehäuse 9/MRD eingesetzt. Diese einfache Montage ermöglicht eine schnelle und effiziente Installation, sodass die Lüftungssysteme rasch in Betrieb genommen werden können.Verfügbare Typen:9/R 160-500 (Art.-Nr.: 36765)9/R 160-700 (Art.-Nr.: 39891)Der Rundkanal für die 160er-Serie ist die perfekte Wahl für alle, die Wert auf eine zuverlässige und effektive Luftführung legen. Man profitiert von einer hohen Qualität und der einfachen Handhabung, um die Lüftungssysteme optimal zu gestalten.
Das Funkmodul UNI-EO erweitert die Universalsteuerungen 5/UNI-FT und 5/UNI-RF, sowie die Smart-Comfort-Steuerungen 5/SC-FT und 5/SC-RF und sorgt für eine stete Kommunikation mit den gekoppelten LUNOS Funkkomponenten. Dazu gehören sowohl die Verarbeitung von empfangenen Sensorwerten und Schaltbefehlen als auch das Senden von Systemzuständen. Automatikmodi können erweitert und optimiert werden. Die Steuerung kann aber auch den Betrieb der angeschlossenen Geräte auf verknüpfte Lüftungskomponenten anpassen. So ist es beispielsweise möglich, dass angeschlossene Lüfter der e²-Serie aktiv Zuluft liefern, wenn ein Ablüfter per Funkbefehl eine geschaltete Bedarfslüftung übermittelt.Abmessungen(H x B x T): 44 mm x 23 mm x 13 mmArt.-Nr. 40091
Das Unterputzmodul UPM-EO ist eine innovative Lösung, die als Sender und Empfänger für Funksignale fungiert und so die Steuerung von Abluftsystemen in Sanierungen und Neubauten revolutioniert. In Verbindung mit einem einfachen Lüfter wie z.B. dem AB 30/60 verleiht das UPM-EO-Modul diesen Lüftern z.B. die Fähigkeit mit anderen EO-Modulen aus der Reihe von LUNOS zu kommunizieren, wodurch sie sich flexibel und drahtlos bedienen lassen. Besonders im Rahmen von Sanierungsprojekten bietet diese Technologie erhebliche Vorteile: Selbst bei bestehenden Bauten kann eine nachträgliche manuelle Steuerung des Lüfters problemlos integriert werden – ohne die Notwendigkeit, zusätzliche Kabel zu verlegen. Dies spart nicht nur Zeit und Kosten, sondern minimiert auch bauliche Eingriffe. Das UPM-EO überzeugt durch seine einfache Handhabung, zuverlässige Signalübertragung und die Möglichkeit, moderne Bedienkonzepte in bestehende Systeme einzuführen. Damit wird es zu einer idealen Wahl für anspruchsvolle Renovierungs- und Modernisierungsprojekte.Einsatzbeispiel: Anschluss eines UPM-EO an einen vorhandenen (Licht-) Schalter. Einsatz eines weiteren UPM-EO an einem AB 30/60. Beide UPM-EO-Module können miteinander gekoppelt werden und so z.B. beim Einschalten des Lichts den Lüfter mit schalten. Ebenso ist eine Integration einer RC-EO Funkfernbedienung möglich, um den Lüfter zusätzlich per Fernbedienung anzusteuern.Abmessungen(H x B x T): 44 mm x 44 mm x 16,9 mmArt.-Nr. 41142
Die Bewegungsmelder der Baureihe 5/BM sind für den Einsatz in dem Ablüfter Typ Silvento ec konzipiert und funktionieren nur in Kombination mit einer Steuerplatine und einem Lüfter. Der Betrieb ohne einen entsprechenden Lüfter ist nicht möglich.Die Bewegungsmelder arbeiten auf Radarbasis und können so kleinste Bewegungen im Raum erkennen. Dabei sind sie für den Nutzer unsichtbar hinter der Designblende des Lüfters versteckt. Die verwendete Radarstrahlung ist selbstverständlich völlig ungefährlich und besitzt eine nur sehr geringe Strahlungsintensität.Die Erfassungsreichweite ist für einen Bereich eines Radius von drei Metern und einem Erfassungswinkel von 120° vor dem verbauten Lüftungsgerät optimiert. In größeren Entfernungen sind eventuell stärkere Bewegungen erforderlich oder der Lüfter muss anders positioniert werden, wenn dieser Bereich miterfasst werden soll.Glastrennwände, Duschkabinen und dünne Türen können von den Radarstrahlen durchdrungen werden und eine Bewegungserfassung ist auch hier. Die Erfassungsreichweite kann dann jedoch je nach Material, Materialstärke und Aufbau eingeschränkt werden.Die Erfassungssensitivität kann in mehreren Stufen erhöht (schnellere Erfassung) oder vermindert (mehr Bewegung erforderlich) werden.Der Bewegungsmelder triggert die eingestellte Bedarfslüftungsstufe des Lüfters. Werkseitig ist eine Laufzeit nach Bewegungserfassung von einer Minute voreingestellt. Diese Laufzeit kann durch Einstellung der Steuerplatine (Nachlaufzeit) bei Bedarf verlängert werden.Bewegungserfassungen (Präsenzerfassung der Nutzer) können zusätzlich zu manueller oder sensorgeführter Funktion oder als eigenständige Lüfteransteuerung (ohne zusätzlichen Schalter oder Sensorik) verwendet werden. Nach DIN 1946-6 handelt es sich bei dieser Steuerungsvariante um eine bedarfsgeführte Lüftersteuerung.EinbauZur Installation des Bewegungsmelder muss die Steuerplatine aus dem Gitterabdeckrahmen entnommen werden. Hierzu wird die Befestigungsschraube gelöst. Der Bewegungsmelder wird an die Steuerplatine gesteckt und wieder in den in den Gitterabdeckrahmen eingesteckt. Der Bewegungsmelder wird anschließend in die Positionierungsstege eingerastet und wieder mit dem Gitterabdeckrahmen verschraubt.Art.-Nr. 40082
BELIMO
Resistance: 200 ΩMountableincl. mounting accessoriesSuitable for actuator:LF.. | NF..A | SF..A
Linear air damper actuator without emergency control function, with connection cableActuating force: 150 NDamper size up to approx.: 1 m²Stroke (toothed rack): 200 mmRunning time motor up to 100 mm: 150 sRated voltage: 24 VOpen / Close: Yes3-point: YesContinuous (2...10 V): No
Rotary actuator with emergency setting function Nominal torque: 4 Nm Flap size up to approx.: 0.8 m² Axle drive universal terminal block: 8...16 mm Running time motor 90°: 40...75 s Running time emergency position 90°: 20 s Rated voltage: 24 V Open / Close: Yes Continuous (2...10 V): No Auxiliary switch: 0
Air damper actuator without emergency control function, with connection terminalsNominal torque: 10 NmDamper size up to approx.: 2 m²Axle centre distance: 8...26.7 mmRunning time motor up to 90°: 150 sRated voltage: 230 VOpen / Close: Yes3-point: YesContinuous (2...10 V): NoAuxiliary switch: 0
Super high-speed rotary actuator without emergency setting function Nominal torque: 16 Nm Flap size up to approx.: 3.2 m² Axle drive universal clamping block: 12...26.7 mm Running time motor 90°: 7 s Rated voltage: 24 V Open / Close: Yes 3-point: No Continuous (2...10 V): No
Rotary actuator with emergency setting function Nominal torque: 2.5 Nm Flap size up to approx.: 0.5 m² Axle drive universal clamping block: 6...12 mm Running time motor 90°: 150 s Running time emergency position 90°: 25 s Rated voltage: 24 V Open / Close: No Continuous (2...10 V): Yes Auxiliary switch: 0
Air damper actuator without emergency setting function, with connection terminalsNominal torque: 20 NmDamper size up to approx.: 4 m²Centre distance: 10...20 mmRunning time motor up to 90°: 150 sRated voltage: 230 VOpen / Close: Yes3-point: YesContinuous (2...10 V): NoAuxiliary switch: 0
High-speed rotary actuator without emergency setting function Nominal torque: 20 Nm Flap size up to approx.: 4 m² Axle drive universal terminal block: 10...20 mm Running time motor 90°: 35 s Rated voltage: 24 V Open / Close: No 3-point: No Continuous (2...10 V): Yes Auxiliary switch: 0
Air damper actuator without emergency setting function, with connection cableNominal torque: 10 NmDamper size up to approx.: 2 m²Centre distance: 8...26.7 mmRunning time motor up to 90°: 150 sRated voltage: 24 VOpen / Close: Yes3-point: YesContinuous (2...10 V): NoAuxiliary switch: 0
High-speed rotary actuator without emergency setting function Nominal torque: 2 Nm Flap size up to approx.: 0.4 m² Axle drive universal clamping block: 6...20 mm Running time motor 90°: 35 s Rated voltage: 230 V Open / Close: Yes 3-point: Yes Continuous (2...10 V): No Auxiliary switch: 1
Air damper actuator without emergency setting function, with connection terminalsNominal torque: 40 NmDamper size up to approx.: 8 m²Centre distance: 12...26.7 mmRunning time motor up to 90°: 150 sRated voltage: 24 VOpen / Close: Yes3-point: NoContinuous (2...10 V): NoAuxiliary switch: 0
Rotary actuator with emergency setting function Nominal torque: 10 Nm Flap size up to approx.: 2 m² Axle drive universal terminal block: 10...25.4 mm Running time motor 90°: 75 s Running time emergency position 90°: 20 s Rated voltage: AC 24...240 V DC 24...125 V Open / Close: Yes Continuous (2...10 V): No Auxiliary switch: 0
Air damper actuator without emergency setting function, with connection cableNominal torque: 20 NmDamper size up to approx.: 4 m²Centre distance: 10...20 mmRunning time motor up to 90°: 150 sRated voltage: 230 VOpen / Close: Yes3-point: YesContinuous (2...10 V): NoAuxiliary switch: 0
Air damper actuator without emergency setting function, with connection cableNominal torque: 2 NmDamper size up to approx.: 0.4 m²Axle centre distance: 6...12.7 mmRunning time motor up to 90°: 75 sRated voltage: 230 VOpen / Close: Yes3-point: YesContinuous (2...10 V): NoAuxiliary switch: 0
Super high-speed rotary actuator without emergency setting function Nominal torque: 16 Nm Flap size up to approx.: 3.2 m² Axle drive universal terminal block: 12...26.7 mm Running time motor 90°: 7 s Rated voltage: 24 V Open / Close: No 3-point: No Continuous (2...10 V): Yes
Rotary actuator with emergency setting function Nominal torque: 20 Nm Flap size up to approx.: 4 m² Axle drive universal terminal block: 10...25.4 mm Running time motor 90°: 150 s Running time emergency position 90°: <20 s Nominal voltage: 24 V Open / closed: No Continuous (2...10 V): Yes Auxiliary switch: 2
Air damper actuator without emergency setting function, with connection cableNominal torque: 10 NmDamper size up to approx.: 2 m²Centre distance: 8...26.7 mmRunning time motor up to 90°: 150 sRated voltage: 24 VOpen / Close: Yes3-point: YesContinuous (2...10 V): NoAuxiliary switch: 1
Rotary actuator with emergency setting function Nominal torque: 2.5 Nm Flap size up to approx.: 0.5 m² Axle drive universal terminal block: 6...12 mm Running time motor 90°: 75 s Running time emergency position 90°: 25 s Rated voltage: 230 V Open / Close: Yes Continuous (2...10 V): No Auxiliary switch: 0
Linear air damper actuator without emergency control function, with connection cableActuating force: 150 NDamper size up to approx.: 1 m²Stroke (toothed rack): 60 mmRunning time motor up to 100 mm: 150 sRated voltage: 24 VOpen / Close: Yes3-point: YesContinuous (2...10 V): No
Rotary actuator with emergency setting function Nominal torque: 2.5 Nm Flap size up to approx.: 0.5 m² Axle drive universal terminal block: 6...12 mm Running time motor 90°: 75 s Running time emergency position 90°: 25 s Rated voltage: 24 V Open / Close: Yes Continuous (2...10 V): No Auxiliary switch: 1
DOBYGRIP
DobyGrip wire rope system is the simple and efficient alternative to threaded rods and chains can be installed up to 6 x faster than conventional systems Simple height adjustment thanks to an external locking lever Versatile in use _z.B for suspending pipework, electrical cables and ventilation ducts Stainless steel
DobyGrip wire rope system is the simple and efficient alternative to threaded rods and chains can be installed up to 6 x faster than conventional systems Simple height adjustment thanks to an external locking lever Versatile in use _z.B for suspending pipework, electrical cables and ventilation ducts Stainless steel
DobyGrip wire rope system is the simple and efficient alternative to threaded rods and chains can be installed up to 6 x faster than conventional systems Simple height adjustment thanks to an external locking lever Versatile in use _z.B for suspending pipework, electrical cables and ventilation ducts Stainless steel
DobyGrip wire rope system is the simple and efficient alternative to threaded rods and chains can be installed up to 6 x faster than conventional systems Simple height adjustment thanks to an external locking lever Versatile in use _z.B for suspending pipework, electrical cables and ventilation ducts Stainless steel
SYSTEMAIR
Ceiling mounting kit for SAVE VSR500.The kit is requiredfor mounting the SAVE VSR500 horizontally under the ceiling .
Systemair tube fan K 250 EC Voltage 230 V Frequency 50/60 Hz Phase 1 ~ Power 115 W Current 0.874 A Max. Volume flow 979 m³/h Speed 2562 r.p.m Sound pressure level at 3m (20m² Sabine) 39.4 dB(A) Weight 4.5 kg Insulation class, motor B Protection class, motor 54 IP Max. Max. fluid temperature 55 °C Max. Max. fluid temperature with speed control 55 °C Description - 100 % controllable - Integrated speed controller - Integrated motor protection - Low noise level - Installation in any mounting position - Mounting bracket included - Reliable and maintenance-free - Energy-efficient, economical and convenient EC fans are intelligent fans with integrated control (commutation unit), which always sets the fan to optimum operation. This means that the proportion of effectively utilised energy is many times higher compared to AC motors. At the same time, the energy input remains extremely low. The EC drive is more energy-efficient and therefore significantly more economical than AC motors, particularly in the controlled range. However, energy-saving fans from Systemair are not only extremely energy-efficient, but also pleasant, convenient and time-saving to install. As the control electronics are integrated into the motor, there is no need to connect to a control cabinet with power and control electronics and the associated wiring work. EC fans also have a longer service life than AC fans due to less wear and tear and lower heat generation and require less maintenance. The compact tube fans in the K-EC series are suitable for installation in pipe systems. For simple and safe installation, all K fans have at least 25 mm long pipe connections in accordance with EN 1506:1997. The fans are equipped with backward curved impeller blades and energy-saving, highly efficient EC external rotor motors. The mounting brackets are included in the scope of delivery. They ensure easy installation and removal of the fan. The fan can be connected to the duct system without vibration using the FK connecting collars available as accessories. The fans are equipped with a potentiometer (0-10V) that can be used to set the operating point directly. The factory setting of the potentiometer is set to a value between 6-10V. To protect the motor from overheating, the fan has a built-in motor protection. The housing is made of galvanised sheet steel. K fans are particularly airtight and achieve tightness class C in accordance with EN 12237:2003. Due to the airtight housing, the terminal box in IP55 and the M20 cable gland in IP 68, installation outdoors and in damp rooms is permitted.
Systemair tube fan K 250M sileo Voltage 230 VFrequency 50 HzPhase 1 ~Electrical input power (P1) 103 WCurrent 0.449 AMax. Volume flow 788 m³/hSpeed 2535 1/minMax. Pumped liquid temperature 70 °CMax. Max. fluid temperature with speed control 70 °CSound pressure level at 3m (20m² Sabine) 41.3 dB(A)Weight 3.9 kgInsulation class F Protection class, motor 44 IPCapacitor 2.5 µF Speed controllable Built-in thermal contacts Can be installed in any position Can be used outdoors Reliable and maintenance-free The K series is suitable for duct mounting. For easy installation, all K fans have at least 25 mm long pipe connections in accordance with EN 1506:1997. The fans are equipped with backward curved impeller blades and external rotor motors. The mounting bracket is included in the scope of delivery. It ensures easy installation and removal of the fan. The fan can be connected to the duct system without vibration using the FK connecting sleeves, which we offer as accessories. The fans can be speed-controlled using a stepless thyristor or a 5-stage transformer. The fan has built-in thermal contacts to protect the motor from overheating. The airtight, folded housing is made of galvanised sheet steel. In accordance with EN 12237:2003, the fan has a leakage rate in accordance with tightness class C. The airtight housing allows the fan to be installed outdoors and in damp rooms.
Pocket filter for Topvex SR devices, filter class F7 With plastic frame and 10 / 12 filter pockets. Can be used as an exhaust air filter. Two filters are required for the Topvex SR09 and SR11!
User-friendly operating unit for SAVE domestic ventilation units with the SAVEControl control system. - Capacitive touch display 3.5" - Frame of the control unit in white- Connection of up to ten control units to one domestic ventilation unit- Up to four control units via the internal power supply- Max. cable length 50 metres- Connection with flat cable and compact plug RJ10 (4P4C)- 15 metre connection cable and Y adapter available as accessories- Wall mounting frame available as an accessory The start screen presents the most important information about operating mode, temperature, air quality and active functions. Access to the complete settings. The control functions are device-specific and can be found in the description of the domestic ventilation units.
Systemair tube fan K 160M sileo Voltage 230 VFrequency 50 HzPhase 1 ~Electrical input power (P1) 53 WCurrent 0.231 AMax. Volume flow 450 m³/hSpeed 2388 1/minMax. Pumped liquid temperature 70 °CMax. Max. fluid temperature with speed control 70 °CSound pressure level at 3m (20m² Sabine) 37.8 dB(A)Weight 3.3 kgInsulation class B Protection class, motor 44 IPCapacitor 1.5 µF Energy class, basic unit E Energy class, basic unit option B Speed controllable Built-in thermal contacts Can be installed in any position Can be used outdoors Reliable and maintenance-free The K series is suitable for duct mounting. For easy installation, all K fans have at least 25 mm long pipe connections in accordance with EN 1506:1997. The fans are equipped with backward curved impeller blades and external rotor motors. The mounting bracket is included in the scope of delivery. It ensures easy installation and removal of the fan. The fan can be connected to the duct system without vibration using the FK connecting sleeves, which we offer as accessories. The fans can be speed-controlled using a stepless thyristor or a 5-stage transformer. The fan has built-in thermal contacts to protect the motor from overheating. The airtight, folded housing is made of galvanised sheet steel. In accordance with EN 12237:2003, the fan has a leakage rate in accordance with tightness class C. The airtight housing allows the fan to be installed outdoors and in damp rooms.
Telescopic suspension for the SAVE VSR 150
Systemair tube fan K 125XL sileo Voltage 230 VFrequency 50 HzPhase 1 ~Electrical input power (P1) 52.7 WCurrent 0.229 AMax. Volume flow 359 m³/hSpeed 2395 1/minMax. Pumped liquid temperature 70 °CMax. Max. fluid temperature with speed control 70 °CSound pressure level at 3m (20m² Sabine) 41.7 dB(A)Weight 2.9 kgInsulation class B Protection class, motor 44 IPCapacitor 1.5 µF Energy class, basic unit E Energy class, basic unit option C Speed controllable Built-in thermal contacts Can be installed in any position Can be used outdoors Reliable and maintenance-free The K series is suitable for duct mounting. For easy installation, all K fans have at least 25 mm long pipe connections in accordance with EN 1506:1997. The fans are equipped with backward curved impeller blades and external rotor motors. The mounting bracket is included in the scope of delivery. It ensures easy installation and removal of the fan. The fan can be connected to the duct system without vibration using the FK connecting sleeves, which we offer as accessories. The fans can be speed-controlled using a stepless thyristor or a 5-stage transformer. The fan has built-in thermal contacts to protect the motor from overheating. The airtight, folded housing is made of galvanised sheet steel. In accordance with EN 12237:2003, the fan has a leakage rate in accordance with tightness class C. The airtight housing allows the fan to be installed outdoors and in damp rooms.
Systemair tube fan K 315L EC Voltage 230 VFrequency 50/60 HzPhase 1 ~Power 340 WCurrent 2.08 AMax. Volume flow 1732 m³/hSpeed 2719 r.p.mSound pressure level at 3m (20m² Sabine) 57.2 dB(A)Weight 7.2 kgInsulation class, motor B Protection class, motor 44 IPMax. Max. fluid temperature 55 °CMax. Max. fluid temperature with speed control 55 °C 100 % controllable Integrated speed controller Integrated motor protection Low noise level Installation in any mounting position Mounting bracket included Reliable and maintenance-free Energy-efficient, economical and convenient EC fans are intelligent fans with integrated control (commutation unit), which always sets the fan to optimum operation. This means that the proportion of effectively utilised energy is many times higher compared to AC motors. At the same time, the energy input remains extremely low. The EC drive is more energy-efficient and therefore significantly more economical than AC motors, particularly in the controlled range.However, energy-saving fans from Systemair are not only extremely energy-efficient, but also pleasant, convenient and time-saving to install. As the control electronics are integrated into the motor, there is no need to connect to a control cabinet with power and control electronics and the associated wiring work. EC fans also have a longer service life than AC fans due to less wear and tear and lower heat generation and require less maintenance. The compact inline fans in the K-EC series are suitable for installation in pipe systems. For simple and safe installation, all K fans have at least 25 mm long pipe connections in accordance with EN 1506:1997. The fans are equipped with backward curved impeller blades and energy-saving, highly efficient EC external rotor motors. The mounting brackets are included in the scope of delivery. They ensure easy installation and removal of the fan. The fans are equipped with a potentiometer (0-10V) that can be used to set the operating point directly. The factory setting of the potentiometer is set to a value between 6-10V. To protect the motor from overheating, the fan has a built-in motor protection. The housing is made of galvanised sheet steel. K fans are particularly airtight and achieve tightness class C in accordance with EN 12237:2003. Due to the airtight housing, the terminal box in IP55 and the M20 cable gland in IP 68, installation outdoors and in damp rooms is permitted.
Systemair tube fan K 250L sileo Voltage 230 VFrequency 50 HzPhase 1 ~Electrical input power (P1) 145 WCurrent 0.632 AMax. Volume flow 979 m³/hSpeed 2562 1/minMax. Pumped liquid temperature 70 °CMax. Max. fluid temperature with speed control 70 °CSound pressure level at 3m (20m² Sabine) 43 dB(A)Weight 4.6 kgInsulation class F Protection class, motor 44 IPCapacitor 3.5 µF Speed controllable Built-in thermal contacts Can be installed in any position Can be used outdoors Reliable and maintenance-free The K series is suitable for duct mounting. For easy installation, all K fans have at least 25 mm long pipe connections in accordance with EN 1506:1997. The fans are equipped with backward curved impeller blades and external rotor motors. The mounting bracket is included in the scope of delivery. It ensures easy installation and removal of the fan. The fan can be connected to the duct system without vibration using the FK connecting sleeves, which we offer as accessories. The fans can be speed-controlled using a stepless thyristor or a 5-stage transformer. The fan has built-in thermal contacts to protect the motor from overheating. The airtight, folded housing is made of galvanised sheet steel. In accordance with EN 12237:2003, the fan has a leakage rate in accordance with tightness class C. The airtight housing allows the fan to be installed outdoors and in damp rooms.
Systemair roof ventilator DVS sileo 190EZ ErP ErP ready ErP 2016/ErP 2018 Nominal data Rated voltage 230 V Frequency 50 Hz phase 1 ~ Electrical input power (P1) 52,4 W Current 0,231 A Max. Volume flow 544 m³/h Rotational speed 2337 1/min Condenser 1,5 µF weight 4,8 kg Temperature data Max. Fluid temperature 65 °C Max. Fluid temperature with speed control 65 °C Sound data Sound pressure level at 4m (free field) 47 dB(A) Sound pressure level at 10m (free field) 39 dB(A) Protection class / classification Insulation class B Protection class, motor IP44 Improved efficiency Speed controllable Motor protection through built-in thermal contacts Excellent noise level Reliable and easy to maintain Extensive range of accessories The DVS, DHS and DVSI sileo fans are characterised by high volume flows at medium pressure differences and very low noise levels and have been specially developed for noise-critical applications. The sileo series has backward-curved centrifugal impellers made of high-performance composite material with highly efficient, profiled 3D blade geometry. All models are equipped with vibration-free suspended, voltage-controllable external rotor motors. When operating DVS/DHS/DVSI sileo roof fans on a frequency converter, an all-pole sinusoidal filter must be used!
Y adapter cable for connecting two control units type CE or CD to a domestic ventilation unit. Flat cable approx. 0.2m
Systemair tube fan K 160 EC Voltage 230 VFrequency 50/60 HzPhase 1 ~Power 79.4 WCurrent 0.628 AMax. Volume flow 544 m³/hSpeed 3105 r.p.mSound pressure level at 3m (20m² Sabine) 46.6 dB(A)Weight 3.3 kgInsulation class, motor B Protection class, motor 44 IPMax. Max. fluid temperature 60 °CMax. Max. fluid temperature with speed control 60 °C 100 % controllable Integrated speed controller Integrated motor protection Low noise level Installation in any mounting position Mounting bracket included Reliable and maintenance-free Energy-efficient, economical and convenient EC fans are intelligent fans with integrated control (commutation unit), which always sets the fan to optimum operation. This means that the proportion of effectively utilised energy is many times higher compared to AC motors. At the same time, the energy input remains extremely low. The EC drive is more energy-efficient and therefore significantly more economical than AC motors, particularly in the controlled range.However, energy-saving fans from Systemair are not only extremely energy-efficient, but also pleasant, convenient and time-saving to install. As the control electronics are integrated into the motor, there is no need to connect to a control cabinet with power and control electronics and the associated wiring work. EC fans also have a longer service life than AC fans due to less wear and tear and lower heat generation and require less maintenance. The compact inline fans in the K-EC series are suitable for installation in pipe systems. For simple and safe installation, all K fans have at least 25 mm long pipe connections in accordance with EN 1506:1997. The fans are equipped with backward curved impeller blades and energy-saving, highly efficient EC external rotor motors. The mounting brackets are included in the scope of delivery. They ensure easy installation and removal of the fan. The fans are equipped with a potentiometer (0-10V) that can be used to set the operating point directly. The factory setting of the potentiometer is set to a value between 6-10V. To protect the motor from overheating, the fan has a built-in motor protection. The housing is made of galvanised sheet steel. K fans are particularly airtight and achieve tightness class C in accordance with EN 12237:2003. Due to the airtight housing, the terminal box in IP55 and the M20 cable gland in IP 68, installation outdoors and in damp rooms is permitted.
Pocket filter for Topvex SR devices, filter class M5 With plastic frame and 10 / 12 filter pockets. Can be used as an exhaust air filter. Two filters are required for the Topvex SR09 and SR11!
Systemair tube fan K 315M EC Voltage 230 VFrequency 50/60 HzPhase 1 ~Power 166 WCurrent 1.14 AMax. Volume flow 1415 m³/hSpeed 2113 r.p.mSound pressure level at 3m (20m² Sabine) 49.7 dB(A)Weight 6 kgInsulation class, motor B Protection class, motor 44 IPMax. Max. fluid temperature 40 °CMax. Max. fluid temperature with speed control 40 °C 100 % controllable Integrated speed controller Integrated motor protection Low noise level Installation in any mounting position Mounting bracket included Reliable and maintenance-free Energy-efficient, economical and convenient EC fans are intelligent fans with integrated control (commutation unit), which always sets the fan to optimum operation. This means that the proportion of effectively utilised energy is many times higher compared to AC motors. At the same time, the energy input remains extremely low. The EC drive is more energy-efficient and therefore significantly more economical than AC motors, particularly in the controlled range.However, energy-saving fans from Systemair are not only extremely energy-efficient, but also pleasant, convenient and time-saving to install. As the control electronics are integrated into the motor, there is no need to connect to a control cabinet with power and control electronics and the associated wiring work. EC fans also have a longer service life than AC fans due to less wear and tear and lower heat generation and require less maintenance. The compact inline fans in the K-EC series are suitable for installation in pipe systems. For simple and safe installation, all K fans have at least 25 mm long pipe connections in accordance with EN 1506:1997. The fans are equipped with backward curved impeller blades and energy-saving, highly efficient EC external rotor motors. The mounting brackets are included in the scope of delivery. They ensure easy installation and removal of the fan. The fans are equipped with a potentiometer (0-10V) that can be used to set the operating point directly. The factory setting of the potentiometer is set to a value between 6-10V. To protect the motor from overheating, the fan has a built-in motor protection. The housing is made of galvanised sheet steel. K fans are particularly airtight and achieve tightness class C in accordance with EN 12237:2003. Due to the airtight housing, the terminal box in IP55 and the M20 cable gland in IP 68, installation outdoors and in damp rooms is permitted.
Systemair tube fan K 125M sileo Voltage 230 VFrequency 50 HzPhase 1 ~Power 29.1 WCurrent 0.172 AMax. Volume flow 187 m³/hSpeed 2483 r.p.mMax. Max. fluid temperature 70 °CMax. Max. fluid temperature with speed control 70 °CSound pressure level at 3m (20m² Sabine) 33.9 dB(A)Weight 2.3 kgInsulation class, motor B Protection class, motor 44 IPCapacitor None µF Energy class, basic unit F Energy class, basic unit option C Speed controllable Built-in thermal contacts Can be installed in any position Can be used outdoors Reliable and maintenance-free The K series is suitable for duct mounting. For easy installation, all K fans have at least 25 mm long pipe connections in accordance with EN 1506:1997. The fans are equipped with backward curved impeller blades and external rotor motors. The mounting bracket is included in the scope of delivery. It ensures easy installation and removal of the fan. The fan can be connected to the duct system without vibration using the FK connecting sleeves, which we offer as accessories. The fans can be speed-controlled using a stepless thyristor or a 5-stage transformer. The fan has built-in thermal contacts to protect the motor from overheating. The airtight, folded housing is made of galvanised sheet steel. In accordance with EN 12237:2003, the fan has a leakage rate in accordance with tightness class C. The airtight housing allows the fan to be installed outdoors and in damp rooms.
Ceiling mounting kit for SAVE VSR 300.The kit is requiredfor mounting the SAVE VSR 300 horizontal under the ceiling .
Systemair tube fan K 125 EC Voltage 230 VFrequency 50 HzPhase 1 ~Power 83 WCurrent 0.678 AMax. Volume flow 482 m³/hSpeed 3308 1/minMax. Max. fluid temperature 60 °CMax. Max. fluid temperature with speed control 60 °CSound pressure level at 3m (20m² Sabine) 45.9 dB(A)Weight 2.8 kgInsulation class, motor B Protection class, motor 54 IP 100 % controllable Integrated speed controller Integrated motor protection Low noise level Installation in any mounting position Mounting bracket included Reliable and maintenance-free Energy-efficient, economical and convenient EC fans are intelligent fans with integrated control (commutation unit), which always sets the fan to optimum operation. This means that the proportion of effectively utilised energy is many times higher compared to AC motors. At the same time, the energy input remains extremely low. The EC drive is more energy-efficient and therefore significantly more economical than AC motors, particularly in the controlled range.However, energy-saving fans from Systemair are not only extremely energy-efficient, but also pleasant, convenient and time-saving to install. As the control electronics are integrated into the motor, there is no need to connect to a control cabinet with power and control electronics and the associated wiring work. EC fans also have a longer service life than AC fans due to less wear and tear and lower heat generation and require less maintenance. The compact inline fans in the K-EC series are suitable for installation in pipe systems. For simple and safe installation, all K fans have at least 25 mm long pipe connections in accordance with EN 1506:1997. The fans are equipped with backward curved impeller blades and energy-saving, highly efficient EC external rotor motors. The mounting brackets are included in the scope of delivery. They ensure easy installation and removal of the fan. The fan can be connected to the duct system without vibration using the FK connecting collars available as accessories. The fans are equipped with a potentiometer (0-10V) that can be used to set the operating point directly. The factory setting of the potentiometer is set to a value between 6-10V. To protect the motor from overheating, the fan has a built-in motor protection. The housing is made of galvanised sheet steel. K fans are particularly airtight and achieve tightness class C in accordance with EN 12237:2003. Due to the airtight housing, the terminal box in IP55 and the M20 cable gland in IP 68, installation outdoors and in damp rooms is permitted.
Thyristor speed controllers enable manual speed control of fans with 230V/50Hz single-phase motors. When installed with the enclosed surface-mounted housing, the protection class of the control unit is IP 54. When flush-mounted without the surface-mounted housing, the protection class is IP 44. Several motors can be connected in parallel as long as the total current does not exceed the rated current of the controller. When selecting a suitable control unit, the starting currents of the fans must be taken into account. Fans that are operated with this control unit must have built-in overheating protection and be suitable for operation with a thyristor controller.
Systemair K 315M inline fan ErP ready ErP 2016/ErP 2018 Nominal dataVoltage 230 VFrequency 50 HzPhase 1 ~Electrical input power (P1) 231 WCurrent 1.01 AMax. Volume flow 1224 m³/hSpeed 2783 1/minCapacitor 5 µFWeight 6.6 kgTemperature dataMax. Max. fluid temperature 70 °CMax. Max. fluid temperature with speed control 70 °CSound dataSound pressure level at 3m (20m² Sabine) 42.7 dB(A)Protection class / classificationInsulation class F Protection class, motor IP44 IP Speed controllable Built-in thermal contacts Installation possible in any mounting position Can be used outdoors Reliable and maintenance-free The K series is suitable for duct mounting. For easy installation, all K fans have at least 25 mm long pipe connections in accordance with EN 1506:1997. The fans are equipped with backward curved impeller blades and external rotor motors. The mounting bracket is included in the scope of delivery. It ensures easy installation and removal of the fan. The fan can be connected to the duct system without vibration using the FK connecting sleeves, which we offer as accessories. The fans can be speed-controlled using a stepless thyristor or a 5-stage transformer. The fan has built-in thermal contacts to protect the motor from overheating. The airtight, folded housing is made of galvanised sheet steel. In accordance with EN 12237:2003, the fan has a leakage rate in accordance with tightness class C. The airtight housing allows the fan to be installed outdoors and in damp rooms.
ARCTIC GARDEN
Frost-proof outdoor tap Whether for gardens, parks, stables, sports grounds or playgrounds - with the frost-proof ARCTIC GARDEN standpipe valves, your outdoor water supply is guaranteed all year round. You also avoid unpleasant and expensive frost damage to your pipes, as frost in water pipes can cause very serious damage. The innovative taps adapt to any environment and their modern technology prevents the tap from freezing. This means that your water supply is guaranteed all year round. They also prevent the pipes from being damaged by frost. Arctic Garden G500: Frost-proof pillar valve Outlet length: 105 mm Stem pipe length: 1400 mm Trunk pipe diameter: ø 22 mm LG = long handle | LGL = lockable long handle | RG = round handle Water withdrawal: also possible during the frost period, as the tap is completely emptied in the CLOSED position Tap jet and flow rate: Can be changed by using different aerators Operation: Wear-free thanks to the use of ceramic discs in frost-proof soil Backflow preventer: in the water inlet Maximum water pressure: 10 bar Main pipe connection: ¾ inch Tap outlet: ¾ inch E X P E R I E N C E-------------------------We hereby declare that all metallic materials used in the fittings of the Arctic range comply with the latest positive list of the German Federal Environment Agency (assessment basis for metallic materials in contact with drinking water) and that the seals used are approved in accordance with DVGW W270 and therefore fulfil the drinking water requirements.When connecting the fitting to the drinking water network, the installation may only be carried out by a licenced specialist company in accordance with DIN 1988 / DIN EN 1717 / EN 806 and must comply with local, national and international standards and regulations.
Stainless steel drip tray for Arctic Garden and Arctic Park variantsPrevents the substrate under the outlet area of the pillar valves from being washed outVisual enhancement of the frost-proof pillar valvesDimensions:300 x 300 x 40 mmNotes on installation:► TWO rubber pipe sleeves are included in the scope of delivery.The thicker sleeve is suitable for fitting the pan tray to an Arctic Garden pillar valve, the thinner one for the Arctic Park versions.► The drip tray can FURTHER be positioned slightly higher on the pillar valve to ensure sufficient clearance for installation.► As long as the screws are not tightened, the drip tray can still be pushed to the desired height.The rubber pipe collar is placed around the standpipe, the retaining plate is PLACED from the inside into the drip tray in front of the TWO through-holes and lightly screwed to the standpipe using the clamp and the two screws.► The drip tray can now be moved and installed at ground level.► To finish the installation, tighten the screws