Skip to main content Jump to search Skip to main navigation
✔ Fast delivery    ✔ Pay by invoice    ✔ Hassle-free returns    ✔ Free technical advice    ✔ Tailored quotations    ✔ Custom-made on request

SPIRAL DUCTS AND VENTILATION PIPES

Spiral seam ducts, ventilation ducts are also called spiral seam pipes. We manufacture the ducts and fittings from galvanised sheet steel or stainless steel (V2A). All fittings are provided with a lip seal. Both the ducts and the fittings comply with leakage class D (the highest class for air ducts). The spiral seam ducts are manufactured in accordance with DIN EN 1506 and DIN EN 12237.

 
To connect two spiral seam ducts, a “spiral seam duct nipple” is required. This is inserted into the ducts. Fittings (bends, T-pieces, Y-pieces, etc.) are inserted directly into the spiral seam duct. No additional connector is required for this. Two fittings are connected to each other with a “spiral seam duct coupling”. 
Wickelfalzrohr rund Edelstahl V2A
Stainless steel spiral duct (V2A)

Stainless steel spiral duct for the installation of ventilation systemsSpiral duct ØD = inner diameterLength 1000 mmMaterial: Stainless steel V2ADesign according to DIN EN 12237Tightness class D according to DIN EN 1507 (highest class of the standard)Intelmann stainless steel spiral duct Application areas: The Intelmann stainless steel spiral duct or spiral seam duct is used for air routing of extract air, outside air, exhaust air and supply air in centralised domestic ventilation or controlled domestic ventilation with heat recovery. The ventilation duct is made of V2A stainless steel. The diameter refers to the inner diameter of the pipe. Connecting the Intelmann spiral ducts in the ventilation system: Nipples or pipe connectors are used to connect the spiral ducts in a ventilation system. Fittings such as bends, branch pieces or T-pieces can be connected directly to the spiral duct. Sockets are used to connect fittings (bends / branch pieces / T-pieces) to each other. A spiral duct is compatible with all other fittings with the same diameter. Two spiral ducts are connected with a nipple.

Variants from €28.04
Regular price: €23.05
Nippel Verbinder Edelstahl für Wickelfalzrohr
Spiral duct nipple (duct connector) with stainless steel seal

Stainless steel nipple for connecting spiral ducts Insertion depth = 40 mm Design in accordance with DIN EN 12237 Tightness class D according to DIN EN 1507 (highest class of the standard) Material: Stainless steel

Variants from €14.63
Regular price: €14.64
Muffe Verbinder Edelstahl für Formteile
Spiral duct socket (moulded part connector) stainless steel

Stainless steel sleeve for connecting moulded parts (bends, T-pieces, branch pieces, reducers, etc.) Insertion depth = 40 mm Design in accordance with DIN EN 12237 Tightness class D according to DIN EN 1507 (highest class of the standard) Material stainless steel V2A The stainless steel sleeve is used to connect moulded parts. It is NOT suitable for connecting a spiral duct to another duct. The sleeve can be used to connect a spiral duct bend and a T-piece.

Variants from €8.35
Regular price: €7.86
Bogen Edelstahl Segmentbauweise Wickelfalzrohr
Spiral duct bend with stainless steel seal

Stainless steel segment bend for spiral duct Insertion length l = 40mm Stainless steel V2A with EPDM double lip seal Tightness class D according to DIN EN 12237, highest tightness class for air ducts the bend is inserted directly into the spiral duct

Variants from €38.80
Regular price: €100.26
Insulated spiral duct
Insulated spiral duct

Insulated spiral duct made of galvanised sheet steelDouble-walled, insulated spiral ducting provides effective protection against condensation.Designed in accordance with DIN EN 12237 and DIN EN 1506Condensation is the main cause of moisture damage in buildings and occurs wherever warm air meets cold surfaces. This can be the case, for example, with a fresh air supply in winter or exhaust air from a heat exchanger. Material: galvanised sheet steelLength: 1 metreInsulation thicknesses: 15 mm| 25 mm | 50 mmMake: Intelmann Possible applications:Outdoor and exhaust air ductTo prevent condensation on the outside of the pipework, the duct must be encased in insulation. An insulation thickness of approx. 15 mm may be sufficient here.Supply and return air ducting through cold roomsHere, the ducts must be protected against heat loss and condensation must be prevented from forming on the inside of the exhaust air duct. The insulation thickness depends on the ambient temperature. If the temperature is outside ( uninsulated attic), an insulation thickness of 50 mm should be selected. In unheated rooms ( unheated cellar), the insulation thickness of 25 mm can be used.

Variants from €24.57
Regular price: €20.94
Insulated nipple (pipe connector)
Insulated nipple (pipe connector)

Insulated nipple for spiral ducts made of galvanised sheet steelDouble-walled, insulated spiral ducting provides effective protection against condensation.Designed in accordance with DIN EN 12237 and DIN EN 1506 Condensation is the main cause of moisture damage in buildings and occurs wherever warm air meets cold surfaces. This can be the case, for example, with a fresh air supply in winter or exhaust air from a heat exchanger. Material: galvanised sheet steelInsulation thickness: 15 mmMake: Intelmann Possible applications:Outside and exhaust air ductTo prevent condensation on the outside of the pipework, the duct must be encased in insulation. An insulation thickness of approx. 15 mm may be sufficient here.Supply and return air ducting through cold roomsHere, the ducts must be protected against heat loss and condensation must be prevented from forming on the inside of the exhaust air duct. The insulation thickness depends on the ambient temperature. If the temperature is outside ( uninsulated loft), an insulation thickness of 50 mm should be selected. In unheated rooms ( unheated cellar), the insulation thickness of 25 mm can be used.

Variants from €9.87
Regular price: €8.02
Insulated sleeve (moulded part connector)
Insulated sleeve (moulded part connector)

Insulated sleeve for spiral ducts made of galvanised sheet steelDouble-walled, insulated spiral ducting provides effective protection against condensation.Design in accordance with DIN EN 12237 and DIN EN 1506Condensation is the main cause of moisture damage in buildings and occurs wherever warm air meets cold surfaces. This can be the case, for example, with a fresh air supply in winter or exhaust air from a heat exchanger.Material: galvanised sheet steelInsulation thickness: 15 mmMake: Intelmann Possible applications:Outside and exhaust air ductTo prevent condensation on the outside of the pipework, the duct must be encased in insulation. An insulation thickness of approx. 15 mm may be sufficient here.Supply and return air ducting through cold roomsHere, the ducts must be protected against heat loss and condensation must be prevented from forming on the inside of the exhaust air duct. The insulation thickness depends on the ambient temperature. If the temperature is outside ( uninsulated loft), an insulation thickness of 50 mm should be selected. In unheated rooms ( unheated cellar), the insulation thickness of 25 mm can be used.

Variants from €6.35
Regular price: €5.16
Insulated spiral-seam bend 30° - 90°
Insulated spiral-seam bend 30° - 90°

Insulated spiral duct made of galvanised sheet steelDouble-walled, insulated spiral duct effectively protects against condensation. Condensation is the main cause of moisture damage in buildings and occurs wherever warm air meets cold surfaces. This can be the case, for example, with a fresh air supply in winter or exhaust air from a heat exchanger. Material: galvanised sheet steelInsulation thickness: 15 mm Possible applications:Outside and exhaust air ductTo prevent condensation on the outside of the pipework, the duct must be encased in insulation. An insulation thickness of approx. 15 mm may be sufficient here.Supply and return air ducting through cold roomsHere, the ducts must be protected against heat loss and condensation must be prevented from forming on the inside of the exhaust air duct. The insulation thickness depends on the ambient temperature. If the temperature is outside ( uninsulated loft), an insulation thickness of 50 mm should be selected. In unheated rooms ( unheated cellar), the insulation thickness of 25 mm can be used.

Variants from €21.45
Regular price: €17.42
Oval spiral duct
Oval spiral duct

The alternative to the rectangular duct in terms of flat design and technology. Made of galvanised slit strips (sheet thickness: 0.6 mm); suitable for an overpressure or underpressure of 700 Pa (70 mm WS)Why oval?Space-saving due to low installation heights without flange connectionsOptimised flow characteristics similar to round air ductsShort installation times thanks to simple plug-in connections and sleevesDesign for demanding visible installations with optional powder coatingHigh stability enables casting in concreteProduction in accordance with VDI 6022 possibleHardly any dirt deposits due to rounded designMoulded parts with lip seals up to tightness class D

Variants from €53.94
Regular price: €17.79
Oval pipe nipple (pipe connection)
Oval pipe nipple (pipe connection)

With lip seal!The alternative to the rectangular duct in terms of flat design and technology. Made of galvanised slit strips (sheet thickness: 0.6 mm); suitable for an overpressure or underpressure of 700 Pa (70 mm WS)Why oval?Space-saving due to low installation heights without flange connectionsOptimised flow characteristics similar to round air ductsShort installation times thanks to simple plug-in connections and sleevesDesign for demanding visible installations with optional powder coatingHigh stability enables casting in concreteProduction in accordance with VDI 6022 possibleHardly any dirt deposits due to rounded designFittings with lip seals up to tightness class D

Variants from €36.58
Regular price: €0.00
Oval pipe socket (fitting connection)
Oval pipe socket (fitting connection)

With lip seal!The alternative to the rectangular duct in terms of flat design and technology. Made of galvanised slit strips (sheet thickness: 0.6 mm); suitable for an overpressure or underpressure of 700 Pa (70 mm WS)Why oval?Space-saving due to low installation heights without flange connectionsOptimised flow characteristics similar to round air ductsShort installation times thanks to simple plug-in connections and sleevesDesign for demanding visible installations with optional powder coatingHigh stability enables casting in concreteProduction in accordance with VDI 6022 possibleHardly any dirt deposits due to rounded designFittings with lip seals up to tightness class D

Variants from €36.58
Regular price: €0.00
Oval tube bend horizontal 45°-90°
Oval tube bend horizontal 45°-90°

With lip seal!The alternative to the rectangular duct in terms of flat design and technology. Made of galvanised slit strips (sheet thickness: 0.6 mm); suitable for an overpressure or underpressure of 700 Pa (70 mm WS)Why oval?Space-saving due to low installation heights without flange connectionsOptimised flow characteristics similar to round air ductsShort installation times thanks to simple plug-in connections and sleevesDesign for demanding visible installations with optional powder coatingHigh stability enables casting in concreteProduction in accordance with VDI 6022 possibleHardly any dirt deposits due to rounded designFittings with lip seals up to tightness class D

Variants from €73.84
Regular price: €0.00
Loading...
Files are being uploaded, please wait...