Intelmann replacement air filter for WS 120 Trio, Trio L and Q, outdoor air, filter class ePM1 50% (F7), equivalent to Maico part no. 0093.1450

Product information "Intelmann replacement air filter for WS 120 Trio, Trio L and Q, outdoor air, filter class ePM1 50% (F7), equivalent to Maico part no. 0093.1450"

Intelmann replacement air filter
  • for WS 120 Trio, Trio L and Q, outdoor air
  • Filter class ePM1 50% (F7)
  • equivalent to Maico part no. 0093.1450
  • Dimensions: 205 x 167 x 45 mm
Manufacturer details (information obligations under the GPSR Product Safety Regulation)
Intelmann GmbH
Rudolf-Diesel-Straße 10
27383 Scheeßel, Deutschland

Angaben zur verantwortlichen Person in der EU (Informationspflichten zur GPSR Produktsicherheitsverordnung)
Intelmann GmbH
Rudolf-Diesel-Straße 10
27383 Scheeßel, Deutschland

W001-Allgemeines-Warnzeichen

Allgemeines Warnzeichen

Stellen Sie sicher, dass der Arbeitsplatz sicher eingerichtet ist und alle erforderlichen Sicherheitsvorkehrungen getroffen wurden. Vermeiden Sie den Zugang unbefugter Personen zur Baustelle. Stellen Sie sicher, dass im Notfall angemessene Erste-Hilfe-Ausrüstung und Kommunikationsmittel verfügbar sind.

W024-Warnung-vor-Handverletzungen

Warnung vor Handverletzungen

Verletzungsgefahr an scharfen Kanten und Blechteilen! – Beim Transport und Einbau Schutzhandschuhe tragen.

W008 Warnung vor Absturzgefahr

Warnung vor Absturzgefahr

Die Installation von Lüftungssystemen in großer Höhe und auf Gerüsten birgt erhebliche Risiken, darunter die Gefahr von Abstürzen, die zu schwerwiegenden Verletzungen oder sogar tödlichen Unfällen führen können.
Skip product gallery

Customers also bought

Maico WS 120 Trio LL central ventilation unit 0095.0655
Maico WS 120 Trio LL central ventilation unit 0095.0655

Brief description: Intelligent ventilation unit with heat and moisture recovery for controlled ventilation with a flow rate of 40 to 120 m3/h. Compact, highly efficient - energy efficiency class A. Compact and highly efficient - energy efficiency class A. Sound and energy-optimised fans in EC technology. KFW subsidisable: Particularly suitable for modern new builds or refurbishments. Very quiet device with extremely low installation height (21 cm) and low weight (25 kg): This makes it particularly suitable for installation in suspended ceilings. Installation on the wall or sloping roof is also possible. External, exhaust, supply and return air spigots in DN 125: Maximum flexibility thanks to 3D air spigots, air duct connection possible on any side. The EPP plug simply needs to be repositioned. Additional flexibility on the supply and return air side: Choice of DN 125 connection or direct air routing with up to four DN 75 air ducts each for supply and return air. Quick and easy installation by breaking out or repositioning the EPP plugs. ISO ePM10 >= 50 % (M5) filter in the extract air and ISO ePM1 >= 50 % (F7) pollen filter in the outside air. Tool-free filter change. The ventilation unit is equipped with a state-of-the-art enthalpy heat exchanger with hygiene certificate in accordance with VDI 6022, Sheet 1. Bypass mode / eco mode: ECO supply air, ECO extract air for passive summer night cooling. Complete separation of the extract air/supply air ducting throughout the entire appliance. This prevents unwanted air recirculation. Viruses (coronavirus) and bacteria are therefore not transmitted. Room air control RLS 1 WR included in the scope of delivery. The WS 120 Trio can be controlled via APP (air@home) and the browser-based web tool (##########_1__-##########_2__) using the integrated LAN interface. Plug & Play: Easy commissioning thanks to free commissioning software and standard USB connection for commissioning, control updates and servicing. USB interface integrated in the device cover - no need to remove the device cover for commissioning/software update. No sensitivity to pressure fluctuations: The integrated / automatic constant volume flow control ensures that the set volume flow is maintained at all times under all operating conditions (filter contamination, air valve settings). This also results in simpler commissioning / air volume measurement at the valves. No adjustment of the volume flows is necessary. Combination sensor (humidity/temperature) integrated as standard in the exhaust air enables demand-led ventilation operation and an intelligent dehumidification strategy (overhumidification protection). The appliance is also characterised by a frost protection strategy that is adapted to actual requirements. The heat recovery unit has a multi-function contact for the control of z.B. Brine earth heat exchanger (uncontrolled pump), operating and fault display, preheating or reheating coil, external dampers or cooling. 2 input contacts (12 V and 230 V) are available for safety shutdowns. Various inputs/outputs enable a control connection to other building services devices z.B. heat pump. Integrated MODBUS interface (TCP/IP and RTU) for integration into the building management system. The optional K-SM plug-in module enables integration into KNX building systems. The optional E-SM plug-in module enables integration into EnOcean systems. Optional additional boards ZP 1 and ZP 2 for extension functions such as z.B. Zone damper, brine earth heat exchanger (controlled pump), filter differential pressure measurement. Maximum appliance flexibility thanks to a wide range of equipment/connection options. Modern modular appliance technology enables a high level of user-friendliness for service and maintenance. Housing: Housing made of black EPP with traffic-white sheet steel cover. Filter can be changed easily without tools. Tight, thermal bridge-free and sound-insulated inner housing. Device surface and inner housing are easy to clean. Filter: ISO ePM10 >= 50 % (M5) filter in the exhaust air and ISO ePM1 >= 50 % (F7) pollen filter in the outside air. Tool-free filter replacement. Operation: RLS 1 WR control panel included in the scope of delivery, 4 air stages, filter change indicator, fault indicator. Additional control panels can be connected in parallel. Mobile operation via APP (air@home) or browser-based web tool (##########_1__-##########_2__) via smartphone, laptop or PC enables ##########_0__. Live reporting, user management. Demand-controlled automatic operation / time-controlled automatic operation. Manual operation / OFF. ECO mode supply air or ECO mode extract air. Filter queries, error messages. Optional RLS T2 WS touchscreen control panel for setting: 2 automatic operating modes (Auto Sensor / Auto Time). 4 manual operating modes (ECO exhaust air / ECO supply air / MANUAL / OFF). Complete commissioning of the WS 120 Trio possible. USB connection for service / commissioning - free MAICO commissioning software. Network integration via integrated LAN interface. Smart-Home ready (z.B. Loxone via Modbus TCP/IP). Modbus TCP/IP and RTU integrated as standard. Optional KNX plug-in module K-SM for integration into building management systems ##########_12__.org. Optional EnOcean plug-in module E-SM for device integration into the EnOcean world www.enocean-allinace.org. Control: Demand-led volume flow control as standard (decisive humidity value). Stepless demand-led adjustment of the air volumes. Integrated over-humidity protection function. 3 temperature sensors in the outside, exhaust and supply air. 1 combination sensor (temperature and humidity) in the exhaust air spigot. Up to 4 external sensors of different types (CO2, VOC, humidity) can be connected. Multifunction contact for controlling z.B. Brine earth heat exchanger (uncontrolled pump), operating and fault display, preheating or reheating coil, external dampers or cooling. Inputs for safety-related switch-off via 12 V contact or 230 V contact (z.B. Smoke detector, fire alarm, differential-pressure-free fireplace). Additional push-button input for triggering time-limited intensive ventilation (shock ventilation). Can be extended via optional additional circuit board ZP 1 to control: 3-way damper (z.B. Air/earth heat exchanger). A controlled pump (z.B. Brine earth heat exchanger). An air damper of a zone control. Switch contact use for external reheating coil. Expandable via optional additional circuit board ZP 2 for: Constant pressure of the EC fans. Differential pressure-controlled filter monitoring. Various inputs and outputs enable a control connection of the ventilation unit with another building services device such as z.B. Heat pump. Approvals and certificates: Test report in accordance with DIN EN 13141-7. Hygiene certificates for casing material (EPP) and heat exchanger. DIBt approval has been applied for. Heat exchanger/heat recovery: Highly efficient enthalpy cross-counterflow heat exchanger. Heat recovery up to 81 % for the L variants and 84 % for the Q variants. Humidity recovery up to 69 %. Hygiene certificate (no bacteria, virus growth/virus transfer) in accordance with VDI 6022, Sheet 1. Heat exchanger can be cleaned with water, antimicrobial. No condensate connection necessary. Bypass: Eco mode: ECO supply air, ECO extract air for passive summer night cooling. Frost protection: Prevention of heat exchanger freezing at low temperatures by monitoring the exhaust air temperature. If there is a risk of frost, the fresh air volume flow is gradually reduced. V versions: Frost protection through integrated preheating coil. Fans: Forward curved centrifugal fans in the exhaust air or outside air. Energy-efficient EC DC motors with integrated constant volume flow control. Possibility of constant pressure control via the optional ZP 2 additional circuit board. 3 ventilation levels continuously adjustable from 40 m3/h to 120 m3/h. Installation instructions: Easy, very time-saving installation by screwing the device directly to the ceiling / wall. Housing cover can be easily removed using screws. The mains cable is fed approx. 2.5 m out of the appliance, the cable for connecting the RLS 1 WR control unit is fed approx. 2 m from the appliance ##########_20__: WS 120 Trio LL, Version: Longitudinal flow, exhaust air left, Delivery volume: 40 m3/h / 120 m3/h, Speed: 2200 1/min, Energy efficiency class: A, Voltage type: Alternating current, Rated voltage: 230 V, Mains frequency: 50 Hz / 60 Hz, SPI value according to DIN EN 13141-7 (A7): 0.29 Wh/m3, Power consumption according to DIN EN 13141-7 (A7): 20 W, Stand-by power consumption: < 1 W, IMax: 1 A, Protection rating: IP 40, DIBT approval: yes, Installation location: wall / ceiling, System type: central, Material: EPP plastic/ galvanised sheet steel, Housing material: EPP plastic, Heat exchanger material: plastic, Colour: black / silver, Weight: 25 kg, Weight with packaging: 28 kg, Filter class: ISO ePM10 >= 50 % (M5) / ISO ePM1 >= 50 % (F7), Connection diameter: 125 mm (outside air/exhaust air), 75 mm (supply air/exhaust air), Number of connection spigots: 10, Width: 600 mm, Height: 210 mm, Depth: 1000 mm, Width with packaging: 720 mm, Height with packaging: 300 mm, Depth with packaging: 1120 mm, Conveying medium temperature at IMax: -20 °C to 50 °C, Max. Heat recovery efficiency according to DIN EN 13141-7 (A7): 81 %, Heat exchanger type: enthalpy cross-counterflow, Bypass: no, Pre-heating coil: no, Enthalpy heat exchanger: yes, Frost protection circuit: yes, Summer circuit: ECO exhaust air / ECO supply air, Filter monitoring: time-controlled, Humidity control: integrated, CO2 control: CO2 sensor for Trio, Air quality control (optional): VOC sensor for Trio, KNX connection (optional): K-SM, MODBUS interface: integrated, Control panel included: RLS 1 WR, App, Control panel (optional): RLS T2 WS, RLS G1 WS, EnOcean radio integration (optional): E-SM, Mobile control: yes, Suitable for roof ventilators: no, Suitable for wall-mounted ventilators: no, Suitable for box ventilators: no, Suitable for circulation ventilators: no, Suitable for duct ventilators: no, Suitable for centrifugal ventilators: no, Suitable for wall-mounted ventilators: no, Suitable for domestic ventilators: no, Suitable for heat recovery systems: no

Regular price: €2,188.33
Maico Central Ventilation Unit WS 120 Trio LLV 0095.0656
Maico Central Ventilation Unit WS 120 Trio LLV 0095.0656

WS 120 Trio LLV - Brief InformationLongitudinally flowed compact and quiet central unit, exhaust air left, with effective heat and moisture recovery, EC fans with constant volume flow control, connection of a duct system, 40-120 m³/h, frost protection through integrated pre-heating coilWS 120 Trio LLV - Product DescriptionBrief DescriptionIntelligent ventilation unit with heat and moisture recovery for controlled supply and exhaust ventilation with a delivery volume of 40 to 120 m³/h.Compact and highly efficient - Energy efficiency class A. Sound and energy-optimised fans in EC technology.KfW funding eligibility and NRW funding are available.Especially suitable for modern new builds or renovations.Very quiet unit with extremely low installation height (21 cm) and low weight (25 kg): Therefore particularly suitable for installation in suspended ceilings. Installation on the wall or roof slope is also possible.Outside, exhaust, supply and extract air connections in DN 125: Maximum flexibility through 3D air connections, duct connection possible on every side. For this, the EPP plug only needs to be repositioned.Additional flexibility on the supply and extract air side: Optional DN 125 connection or direct air guidance with up to four DN 75 air ducts each for supply and extract air. Simple and quick installation by breaking out or repositioning the EPP plugs.ISO ePM10 ≥ 50 % (M5) filter in the extract air and ISO ePM1 ≥ 60 % (F7) pollen filter in the outside air.Tool-free filter change.The ventilation unit is equipped with a state-of-the-art enthalpy heat exchanger with hygiene certificate according to VDI 6022, Sheet 1.Bypass operation / Eco mode: ECO supply air, ECO extract air for passive summer night cooling.Complete separation of extract/supply air flow throughout the unit. This prevents unwanted recirculation. Viruses (e.g. coronavirus) and bacteria are thus not transmitted.Room air control RLS 1 WR included in delivery.The WS 120 Trio can be controlled via APP (Maico@home).Plug & Play: Easy commissioning through free commissioning software and standard USB connection for commissioning, control update and service.USB interface integrated in the device cover – no need to remove the device cover during commissioning/software update.No sensitivity to pressure fluctuations: The integrated/automatic constant volume flow control ensures permanent compliance with the set volume flow under all operating conditions (e.g. filter contamination, air valve settings). This also results in easier commissioning/air volume measurement at the valves. No balancing of volume flows is necessary.Standard integrated combined sensor (humidity/temperature) in the extract air enables demand-controlled ventilation operation as well as an intelligent dehumidification strategy (over-humidity protection). Furthermore, the unit features a frost protection strategy adapted to actual demand.The heat recovery unit has a multifunction contact for controlling e.g. brine-earth heat exchanger (unregulated pump), operating and fault indication, pre-heating or post-heating coil, outside flaps or cooling.2 input contacts (12 V and 230 V) are available for e.g. safety shutdowns.Various inputs/outputs allow control connection to other building technology devices, e.g. heat pump.Integrated MODBUS interface (TCP/IP and RTU) for integration into building management systems.Integrated BACnet interface (TCP/IP) for integration into building management systems.Optional plug-in module K-SM enables integration into KNX building systems.Optional plug-in module E-SM enables integration into EnOcean systems.Optional additional circuit boards ZP 1 and ZP 2 for expansion functions such as zone damper, brine-earth heat exchanger (regulated pump), filter differential pressure measurement.Maximum device flexibility through various equipment/connection options.Modern device module technology enables high user-friendliness for service and maintenance.HousingHousing made of black EPP with traffic white steel sheet cover.Filter change possible without tools.Tight, thermal bridge-free and sound-insulated inner housing.Device surface and inner housing are easy to clean.FiltersISO ePM10 ≥ 50 % (M5) filter in the extract air and ISO ePM1 ≥ 60 % (F7) pollen filter in the outside air.Tool-free filter change.OperationControl unit RLS 1 WR included, 4 air levels, filter change indicator, fault indicator.Additional control units can be connected in parallel.Mobile operation via APP (Maico@home).Live reporting, user management.Demand-controlled automatic operation / time-controlled automatic operation.Manual operation / OFF.ECO mode supply air or ECO mode extract air.Filter queries, error messages.Optional touchscreen control unit RLS T2 WS for setting:2 automatic operating modes (Auto Sensor / Auto Time).4 manual operating modes (ECO Extract / ECO Supply / MANUAL / OFF).Complete commissioning of the WS 120 Trio possible.Optional design control unit RLS G1 WS:ON/OFF5 levelsAutomatic operationECO supply air, ECO extract airFilter change and fault indicatorUSB connection for service / commissioning - free MAICO commissioning software.Network integration via integrated LAN interface.Smart-Home ready (e.g. Loxone via Modbus TCP/IP).Modbus TCP/IP and RTU integrated as standard.Optional KNX plug-in module K-SM for integration into building management www.knx.org.Optional EnOcean plug-in module E-SM for device integration into the “EnOcean world” www.enocean-allinace.org.ControlStandard demand-controlled volume flow control (“relevant humidity value”).Stepless demand-controlled adjustment of air volumes.Integrated over-humidity protection function.3 temperature sensors in outside, exhaust and supply air.1 combined sensor (temperature and humidity) in the extract air connection.Up to 4 external sensors of various types (CO2, VOC, humidity) can be connected.Multifunction contact for controlling e.g. brine-earth heat exchanger (unregulated pump), operating and fault indication, pre-heating or post-heating coil, outside flaps or cooling.Inputs for safety shutdown via 12 V contact or 230 V contact (e.g. smoke detector, fire alarm, pressureless fireplace).Additional push-button input for triggering time-limited intensive ventilation (shock ventilation).Expandable via optional additional circuit board ZP 1 for controlling:3-way damper (e.g. air-earth heat exchanger).A regulated pump (e.g. brine-earth heat exchanger).An air damper of a zone control.Switch contact use for external post-heating coil.Expandable via optional additional circuit board ZP 2 for:Pressure constancy of EC fans.Differential pressure controlled filter monitoring.Various inputs and outputs allow control connection of the ventilation unit with another building technology device such as a heat pump.Approvals and CertificatesTest report according to DIN EN 13141-7.Hygiene certificates for housing material (EPP) and heat exchanger.DIBt approval is applied for.Heat Exchanger/Heat RecoveryHighly efficient enthalpy cross-counterflow heat exchanger.Heat recovery up to 86 % for L variants and 91 % for Q variants.Moisture recovery up to 69 %.Hygiene certificate (no bacteria, virus growth/virus transmission) according to VDI 6022, Sheet 1.Heat exchanger washable with water, antimicrobial.No condensate connection necessary.Summer ModeEco mode: ECO supply air, ECO extract air for passive summer night cooling.Frost ProtectionPrevention of heat exchanger freezing at low temperatures by monitoring the exhaust air temperature.In case of frost risk, the outside air volume flow is gradually reduced.V versions: Frost protection through integrated pre-heating coil.FansForward curved radial fans in the exhaust air and outside air.Energy-efficient EC direct current motors with integrated volume flow constancy control.Possibility of pressure constancy control via optional additional circuit board ZP 2.3 ventilation levels from 40 m³/h to 120 m³/h continuously adjustable.Installation NotesEasy, very time-saving installation by directly screwing the unit to the ceiling/wall.Housing cover easily removable via screws.The ventilation unit is delivered ready for connection.The mains connection cable (2.5 m) and the control cable (2 m) of the room air control RLS 1 WR are already wired in the ventilation unit at the factory.Installation / Operation / Maintenance Wiring diagramsCustomer service request/orderInstallation and operating instructions wibutler: pdf | onlineSafety instructions WS: pdf | onlineOperating instructions: pdf | onlineInstallation, commissioning and maintenance instructions: pdf | onlineQuick start operating instructions: pdf | online ArticleWS 120 Trio LLVVersionLongitudinal flow, exhaust air left, integrated pre-heating coilDelivery volume40 m³/h - 120 m³/hSpeed2,200 1/minSEC average-36.82 kWh/(m²*a)Energy efficiency classAType of voltageAlternating currentRated voltage230 VMains frequency50 Hz / 60 HzSPI value according to DIN EN 13141-7 (A7)0.29 Wh/m³Power consumption according to DIN EN 13141-7 (A7)20 WStand-by power consumption< 1 WIMax5 AProtection classIP 00DIBt approvalapplied forInstallation locationWall / ceilingSystem typecentralMaterialPlastic EPP/ galvanized steel sheetHousing materialPlastic EPPHeat exchanger materialPlasticColourblack / traffic white (RAL 9016)Weight25 kgWeight with packaging28 kgFilter classISO ePM10 ≥ 50 % (M5) / ISO ePM1 ≥ 60 % (F7)Connection diameter125 mm (outside air / exhaust air / supply air / extract air), 75 mm (supply air / extract air)Width600 mmHeight210 mmDepth1,000 mmWidth with packaging720 mmHeight with packaging300 mmDepth with packaging1,120 mmTransport medium temperature at IMax-20 °C to 50 °CMax. heat supply rate according to DIN EN 13141-7 (A7)81 %Heat exchanger typeEnthalpy cross-counterflowMoisture recovery with enthalpy heat exchanger according to DIN EN 13141-7 (A2)69 %Extract air positionleftBypassnoPre-heating coilintegratedEnthalpy heat exchangeryesFrost protection circuityesSummer modeECO extract air / ECO supply airFilter monitoringtime-controlledHumidity controlintegratedCO2 control (optional)Trio CO2 E, Trio CO2 IAir quality control (optional)Trio VOC E, Trio VOC IKNX connection (optional)K-SMMODBUS interfaceintegratedControl unit includedRLS 1 WR, AppControl unit (optional)RLS T2 WS, RLS G1 WSRadio integration EnOcean (optional)E-SMMobile controlyesSound pressure level housing radiation32 dB / distance 1 m, sound absorption 10 m²Packaging unit1 pieceRangeKGTIN (EAN)4012799956563Article number0095.0656

Regular price: €2,370.93
Maico Central Ventilation Unit WS 120 Trio LR 0095.0657
Maico Central Ventilation Unit WS 120 Trio LR 0095.0657

WS 120 Trio LR - Brief InformationLongitudinally flowed compact and quiet central unit, exhaust air on the right, with effective heat and moisture recovery, EC fans with constant volume flow control, connection to a duct system, 40-120 m³/hWS 120 Trio LR - Product DescriptionBrief DescriptionIntelligent ventilation unit with heat and moisture recovery for controlled supply and exhaust ventilation with a delivery volume of 40 to 120 m³/h.Compact and highly efficient - Energy efficiency class A. Sound and energy-optimised fans in EC technology.Eligible for KfW funding and NRW funding.Especially suitable for modern new builds or renovations.Very quiet unit with extremely low installation height (21 cm) and low weight (25 kg): therefore particularly suitable for installation in suspended ceilings. Installation on the wall or pitched roof is also possible.Outside, exhaust, supply and extract air connections in DN 125: Maximum flexibility through 3D air connections, duct connection possible on every side. For this, the EPP plug simply needs to be repositioned.Additional flexibility on the supply and extract air side: optionally DN 125 connection or direct air guidance with up to four DN 75 air ducts each for supply and extract air. Easy and quick installation by breaking out or repositioning the EPP plugs.ISO ePM10 ≥ 50 % (M5) filter in the extract air and ISO ePM1 ≥ 60 % (F7) pollen filter in the outside air.Tool-free filter change.The ventilation unit is equipped with a state-of-the-art enthalpy heat exchanger with hygiene certificate according to VDI 6022, Sheet 1.Bypass operation / Eco operation: ECO supply air, ECO extract air for passive summer night cooling.Complete separation of extract/supply air flow throughout the unit. This prevents unwanted recirculation. Viruses (e.g. coronavirus) and bacteria are thus not transmitted.Room air control RLS 1 WR included in delivery.The WS 120 Trio can be controlled via APP (Maico@home).Plug & Play: Easy commissioning through free commissioning software and standard USB connection for commissioning, control update and service.USB interface integrated in the unit cover – no need to remove the unit cover during commissioning/software update.No sensitivity to pressure fluctuations: The integrated/automatic constant volume flow control ensures permanent compliance with the set volume flow under all operating conditions (e.g. filter contamination, air valve settings). This also results in easier commissioning/air volume measurement at the valves. No balancing of volume flows is necessary.Standard integrated combined sensor (humidity/temperature) in the extract air enables demand-controlled ventilation operation as well as an intelligent dehumidification strategy (over-humidity protection). Furthermore, the unit features a frost protection strategy adapted to the actual demand.The heat recovery unit has a multifunction contact for controlling e.g. brine geothermal heat exchanger (unregulated pump), operating and fault indication, preheating or reheating coil, external flaps or cooling.2 input contacts (12 V and 230 V) are available for e.g. safety shutdowns.Various inputs/outputs allow control connection to other building services devices, e.g. heat pump.Integrated MODBUS interface (TCP/IP and RTU) for integration into building management systems.Integrated BACnet interface (TCP/IP) for integration into building management systems.Optional plug-in module K-SM enables integration into KNX building systems.Optional plug-in module E-SM enables integration into EnOcean systems.Optional additional circuit boards ZP 1 and ZP 2 for expansion functions such as zone damper, brine geothermal heat exchanger (regulated pump), filter differential pressure measurement.Maximum device flexibility through various equipment/connection options.Modern device module technology enables high user-friendliness for service and maintenance.HousingHousing made of black EPP with traffic white steel sheet cover.Filter change possible without tools.Tight, thermal bridge-free and sound-insulated inner housing.Unit surface and inner housing are easy to clean.FiltersISO ePM10 ≥ 50 % (M5) filter in the extract air and ISO ePM1 ≥ 60 % (F7) pollen filter in the outside air.Tool-free filter change.OperationControl unit RLS 1 WR included, 4 air levels, filter change indicator, fault indicator.Additional control units can be connected in parallel.Mobile operation via APP (Maico@home).Live reporting, user management.Demand-controlled automatic operation / time-controlled automatic operation.Manual operation / OFF.ECO operation supply air or ECO operation extract air.Filter queries, error messages.Optional touchscreen control unit RLS T2 WS for setting:2 automatic operating modes (Auto Sensor / Auto Time).4 manual operating modes (ECO Extract air / ECO Supply air / MANUAL / OFF).Complete commissioning of the WS 120 Trio possible.Optional design control unit RLS G1 WS:ON/OFF5 levelsAutomatic operationECO supply air, ECO extract airFilter change and fault indicatorUSB connection for service / commissioning - free MAICO commissioning software.Network integration via integrated LAN interface.Smart-Home ready (e.g. Loxone via Modbus TCP/IP).Modbus TCP/IP and RTU integrated as standard.Optional KNX plug-in module K-SM for integration into building management systems www.knx.org.Optional EnOcean plug-in module E-SM for device integration into the “EnOcean world” www.enocean-allinace.org.ControlStandard demand-controlled volume flow control (“relevant humidity value”).Stepless demand-controlled adjustment of air volumes.Integrated over-humidity protection function.3 temperature sensors in outside, exhaust and supply air.1 combined sensor (temperature and humidity) in the extract air connection.Up to 4 external sensors of various types (CO2, VOC, humidity) can be connected.Multifunction contact for controlling e.g. brine geothermal heat exchanger (unregulated pump), operating and fault indication, preheating or reheating coil, external flaps or cooling.Inputs for safety shutdown via 12 V contact or 230 V contact (e.g. smoke detector, fire alarm, pressureless fireplace).Additional push-button input for triggering time-limited intensive ventilation (shock ventilation).Expandable via optional additional circuit board ZP 1 for controlling:3-way damper (e.g. air-geothermal heat exchanger).A regulated pump (e.g. brine geothermal heat exchanger).An air damper of a zone control.Switch contact use for external reheating coil.Expandable via optional additional circuit board ZP 2 for:Pressure constancy of EC fans.Differential pressure-controlled filter monitoring.Various inputs and outputs allow control connection of the ventilation unit with another building services device such as a heat pump.Approvals and CertificatesTest report according to DIN EN 13141-7.Hygiene certificates for housing material (EPP) and heat exchanger.DIBt approval is applied for.Heat Exchanger/Heat RecoveryHighly efficient enthalpy cross-counterflow heat exchanger.Heat recovery up to 86 % for the L variants and 91 % for the Q variants.Moisture recovery up to 69 %.Hygiene certificate (no bacteria, virus growth/virus transmission) according to VDI 6022, Sheet 1.Heat exchanger cleanable with water, antimicrobial.No condensate connection necessary.Summer ModeEco operation: ECO supply air, ECO extract air for passive summer night cooling.Frost ProtectionPrevention of heat exchanger freezing at low temperatures by monitoring the exhaust air temperature.In case of frost risk, the outside air volume flow is gradually reduced.V versions: Frost protection by integrated preheating coil.FansForward curved radial fans in the exhaust air and outside air.Energy-efficient EC direct current motors with integrated volume flow constancy control.Possibility of pressure constancy control via optional additional circuit board ZP 2.3 ventilation levels from 40 m³/h to 120 m³/h continuously adjustable.Installation InstructionsEasy, very time-saving installation by directly screwing the unit to the ceiling/wall.Unit cover easily removable via screws.The ventilation unit is delivered ready for connection.The mains connection cable (2.5 m) and the control cable (2 m) of the room air control RLS 1 WR are already wired in the ventilation unit at the factory.Installation / Operation / Maintenance Wiring diagramsCustomer service request/orderInstallation and operating instructions wibutler: pdf | onlineSafety instructions WS: pdf | onlineOperating instructions: pdf | onlineInstallation, commissioning and maintenance instructions: pdf | onlineQuick start operating instructions: pdf | online ArticleWS 120 Trio LRVersionLongitudinal flow, exhaust air rightDelivery volume40 m³/h - 120 m³/hSpeed2,200 1/minSEC average-36.82 kWh/(m²*a)Energy efficiency classAType of voltageAlternating currentRated voltage230 VMains frequency50 Hz / 60 HzSPI value according to DIN EN 13141-7 (A7)0.29 Wh/m³Power consumption according to DIN EN 13141-7 (A7)20 WStand-by power consumption< 1 WIMax1 AProtection classIP 00DIBt approvalapplied forInstallation locationWall / ceilingSystem typecentralMaterialPlastic EPP/ galvanized steel sheetHousing materialPlastic EPPHeat exchanger materialPlasticColourBlack / traffic white (RAL 9016)Weight25 kgWeight with packaging28 kgFilter classISO ePM10 ≥ 50 % (M5) / ISO ePM1 ≥ 60 % (F7)Connection diameter125 mm (outside air / exhaust air / supply air / extract air), 75 mm (supply air / extract air)Width600 mmHeight210 mmDepth1,000 mmWidth with packaging720 mmHeight with packaging300 mmDepth with packaging1,120 mmTransport medium temperature at IMax-20 °C to 50 °CMax. heat supply rate according to DIN EN 13141-7 (A7)81 %Heat exchanger typeEnthalpy cross-counterflowMoisture recovery with enthalpy heat exchanger according to DIN EN 13141-7 (A2)69 %Extract air positionrightBypassnoPreheating coilnoEnthalpy heat exchangeryesFrost protection circuityesSummer modeECO extract air / ECO supply airFilter monitoringtime-controlledHumidity controlintegratedCO2 control (optional)Trio CO2 E, Trio CO2 IAir quality control (optional)Trio VOC E, Trio VOC IKNX connection (optional)K-SMMODBUS interfaceintegratedControl unit includedRLS 1 WR, AppControl unit (optional)RLS T2 WS, RLS G1 WSRadio integration EnOcean (optional)E-SMMobile controlyesSound pressure level housing radiation32 dB / distance 1 m, sound absorption 10 m²Packaging unit1 pieceRangeKGTIN (EAN)4012799956570Article number0095.0657

Regular price: €2,188.33
Maico Central Ventilation Unit WS 120 Trio LRV 0095.0658
Maico Central Ventilation Unit WS 120 Trio LRV 0095.0658

WS 120 Trio LRV - Brief InformationLongitudinally flowed compact and quiet central unit, exhaust air on the right, with effective heat and moisture recovery, EC fans with constant volume flow control, connection to a duct system, 40-120 m³/h, frost protection through integrated pre-heating coilWS 120 Trio LRV - Product DescriptionBrief DescriptionIntelligent ventilation unit with heat and moisture recovery for controlled supply and exhaust ventilation with a delivery volume of 40 to 120 m³/h.Compact and highly efficient - Energy efficiency class A. Sound and energy-optimised fans in EC technology.Eligible for KfW funding and NRW funding.Especially suitable for modern new builds or renovations.Very quiet unit with extremely low installation height (21 cm) and low weight (25 kg): Therefore particularly suitable for installation in suspended ceilings. Installation on the wall or roof slope is also possible.Outside, exhaust, supply and extract air connections in DN 125: Maximum flexibility through 3D air connections, duct connection possible on every side. For this, the EPP plug only needs to be repositioned.Additional flexibility on the supply and extract air side: Optional DN 125 connection or direct air guidance with up to four DN 75 air ducts each for supply and extract air. Simple and quick installation by breaking out or repositioning the EPP plugs.ISO ePM10 ≥ 50 % (M5) filter in the extract air and ISO ePM1 ≥ 60 % (F7) pollen filter in the outside air.Tool-free filter change.The ventilation unit is equipped with a state-of-the-art enthalpy heat exchanger with hygiene certificate according to VDI 6022, Sheet 1.Bypass operation / Eco mode: ECO supply air, ECO extract air for passive summer night cooling.Complete separation of extract/supply air flow throughout the unit. This prevents unwanted recirculation. Viruses (e.g. coronavirus) and bacteria are thus not transmitted.Room air control RLS 1 WR included in delivery.The WS 120 Trio can be controlled via APP (Maico@home).Plug & Play: Easy commissioning through free commissioning software and standard USB connection for commissioning, control update and service.USB interface integrated in the device cover – no need to remove the device cover during commissioning/software update.No sensitivity to pressure fluctuations: The integrated/automatic constant volume flow control ensures permanent compliance with the set volume flow under all operating conditions (e.g. filter contamination, air valve settings). This also results in easier commissioning/air volume measurement at the valves. No balancing of volume flows is necessary.Standard integrated combined sensor (humidity/temperature) in the extract air enables demand-controlled ventilation operation as well as an intelligent dehumidification strategy (over-humidity protection). Furthermore, the unit features a frost protection strategy adapted to the actual demand.The heat recovery unit has a multifunction contact for controlling e.g. brine-earth heat exchanger (unregulated pump), operating and fault indication, pre-heating or post-heating coil, outside flaps or cooling.2 input contacts (12 V and 230 V) are available for e.g. safety shutdowns.Various inputs/outputs allow control connection to other building technology devices, e.g. heat pump.Integrated MODBUS interface (TCP/IP and RTU) for integration into building management systems.Integrated BACnet interface (TCP/IP) for integration into building management systems.Optional plug-in module K-SM enables integration into KNX building systems.Optional plug-in module E-SM enables integration into EnOcean systems.Optional additional circuit boards ZP 1 and ZP 2 for expansion functions such as zone damper, brine-earth heat exchanger (regulated pump), filter differential pressure measurement.Maximum device flexibility through various equipment/connection options.Modern device module technology enables high user-friendliness for service and maintenance.HousingHousing made of black EPP with traffic white steel sheet cover.Filter change possible without tools.Tight, thermal bridge-free and sound-insulated inner housing.Device surface and inner housing are easy to clean.FiltersISO ePM10 ≥ 50 % (M5) filter in the extract air and ISO ePM1 ≥ 60 % (F7) pollen filter in the outside air.Tool-free filter change.OperationControl unit RLS 1 WR included, 4 air levels, filter change indicator, fault indicator.Additional control units can be connected in parallel.Mobile operation via APP (Maico@home).Live reporting, user management.Demand-controlled automatic operation / time-controlled automatic operation.Manual operation / OFF.ECO mode supply air or ECO mode extract air.Filter queries, error messages.Optional touchscreen control unit RLS T2 WS for setting:2 automatic operating modes (Auto Sensor / Auto Time).4 manual operating modes (ECO Extract / ECO Supply / MANUAL / OFF).Complete commissioning of the WS 120 Trio possible.Optional design control unit RLS G1 WS:ON/OFF5 levelsAutomatic operationECO supply air, ECO extract airFilter change and fault indicatorUSB connection for service / commissioning - free MAICO commissioning software.Network integration via integrated LAN interface.Smart-Home ready (e.g. Loxone via Modbus TCP/IP).Modbus TCP/IP and RTU integrated as standard.Optional KNX plug-in module K-SM for integration into building management systems www.knx.org.Optional EnOcean plug-in module E-SM for device integration into the “EnOcean world” www.enocean-alliance.org.ControlStandard demand-controlled volume flow control (“relevant humidity value”).Stepless demand-controlled adjustment of air volumes.Integrated over-humidity protection function.3 temperature sensors in outside, exhaust and supply air.1 combined sensor (temperature and humidity) in the extract air connection.Up to 4 external sensors of various types (CO2, VOC, humidity) can be connected.Multifunction contact for controlling e.g. brine-earth heat exchanger (unregulated pump), operating and fault indication, pre-heating or post-heating coil, outside flaps or cooling.Inputs for safety shutdown via 12 V contact or 230 V contact (e.g. smoke detector, fire alarm, pressureless fireplace).Additional push-button input for triggering time-limited intensive ventilation (shock ventilation).Expandable via optional additional circuit board ZP 1 for controlling:3-way damper (e.g. air-earth heat exchanger).A regulated pump (e.g. brine-earth heat exchanger).An air damper of a zone control.Switch contact use for external post-heating coil.Expandable via optional additional circuit board ZP 2 for:Pressure constancy of EC fans.Differential pressure controlled filter monitoring.Various inputs and outputs allow control connection of the ventilation unit with another building technology device such as a heat pump.Approvals and CertificatesTest report according to DIN EN 13141-7.Hygiene certificates for housing material (EPP) and heat exchanger.DIBt approval is applied for.Heat Exchanger/Heat RecoveryHighly efficient enthalpy cross-counterflow heat exchanger.Heat recovery up to 86 % for the L variants and 91 % for the Q variants.Moisture recovery up to 69 %.Hygiene certificate (no bacteria, virus growth/virus transmission) according to VDI 6022, Sheet 1.Heat exchanger washable with water, antimicrobial.No condensate connection necessary.Summer ModeEco mode: ECO supply air, ECO extract air for passive summer night cooling.Frost ProtectionPrevention of heat exchanger freezing at low temperatures by monitoring the exhaust air temperature.In case of frost risk, the outside air volume flow is gradually reduced.V versions: Frost protection through integrated pre-heating coil.FansForward-curved radial fans in the exhaust and outside air.Energy-efficient EC direct current motors with integrated volume flow constancy control.Possibility of pressure constancy control via optional additional circuit board ZP 2.3 ventilation levels from 40 m³/h to 120 m³/h continuously adjustable.Installation InstructionsEasy, very time-saving installation by directly screwing the unit to the ceiling/wall.Housing cover easily removable via screws.The ventilation unit is delivered ready for connection.The mains connection cable (2.5 m) and the control cable (2 m) of the room air control RLS 1 WR are already wired in the ventilation unit at the factory.Installation / Operation / Maintenance Wiring diagramsCustomer service request/orderInstallation and operating instructions wibutler: pdf | onlineSafety instructions WS: pdf | onlineOperating instructions: pdf | onlineInstallation, commissioning and maintenance instructions: pdf | onlineQuick start operating instructions: pdf | online ArticleWS 120 Trio LRVVersionLongitudinal flow, exhaust air right, integrated pre-heating coilDelivery volume40 m³/h - 120 m³/hSpeed2,200 1/minSEC average-36.82 kWh/(m²*a)Energy efficiency classAVoltage typeAlternating currentRated voltage230 VMains frequency50 Hz / 60 HzSPI value according to DIN EN 13141-7 (A7)0.29 Wh/m³Power consumption according to DIN EN 13141-7 (A7)20 WStand-by power consumption< 1 WIMax5 AProtection classIP 00DIBt approvalapplied forInstallation locationWall / ceilingSystem typecentralMaterialPlastic EPP/ galvanized steel sheetHousing materialPlastic EPPHeat exchanger materialPlasticColourblack / traffic white (RAL 9016)Weight25 kgWeight with packaging28 kgFilter classISO ePM10 ≥ 50 % (M5) / ISO ePM1 ≥ 60 % (F7)Connection diameter125 mm (outside air / exhaust air / supply air / extract air), 75 mm (supply air / extract air)Width600 mmHeight210 mmDepth1,000 mmWidth with packaging720 mmHeight with packaging300 mmDepth with packaging1,120 mmTransport medium temperature at IMax-20 °C to 50 °CMax. heat supply rate according to DIN EN 13141-7 (A7)81 %Heat exchanger typeEnthalpy cross-counterflowMoisture recovery with enthalpy heat exchanger according to DIN EN 13141-7 (A2)69 %Exhaust air positionrightBypassnoPre-heating coilintegratedEnthalpy heat exchangeryesFrost protection circuityesSummer modeECO extract air / ECO supply airFilter monitoringtime-controlledHumidity controlintegratedCO2 control (optional)Trio CO2 E, Trio CO2 IAir quality control (optional)Trio VOC E, Trio VOC IKNX connection (optional)K-SMMODBUS interfaceintegratedControl unit includedRLS 1 WR, AppControl unit (optional)RLS T2 WS, RLS G1 WSRadio integration EnOcean (optional)E-SMMobile controlyesSound pressure level housing radiation32 dB / distance 1 m, sound absorption 10 m²Packaging unit1 pieceRangeKGTIN (EAN)4012799956587Article number0095.0658

Regular price: €2,370.93
Maico WS 120 Trio QL central ventilation unit 0095.0659
Maico WS 120 Trio QL central ventilation unit 0095.0659

Brief description: Intelligent ventilation unit with heat and moisture recovery for controlled ventilation with a flow rate of 40 to 120 m3/h. Compact, highly efficient - energy efficiency class A. Compact and highly efficient - energy efficiency class A. Sound and energy-optimised fans in EC technology. KFW subsidisable: Particularly suitable for modern new builds or refurbishments. Very quiet device with extremely low installation height (21 cm) and low weight (25 kg): This makes it particularly suitable for installation in suspended ceilings. Installation on the wall or sloping roof is also possible. External, exhaust, supply and return air spigots in DN 125: Maximum flexibility thanks to 3D air spigots, air duct connection possible on any side. The EPP plug simply needs to be repositioned. Additional flexibility on the supply and return air side: Choice of DN 125 connection or direct air routing with up to four DN 75 air ducts each for supply and return air. Quick and easy installation by breaking out or repositioning the EPP plugs. ISO ePM10 >= 50 % (M5) filter in the extract air and ISO ePM1 >= 50 % (F7) pollen filter in the outside air. Tool-free filter change. The ventilation unit is equipped with a state-of-the-art enthalpy heat exchanger with hygiene certificate in accordance with VDI 6022, Sheet 1. Bypass mode / eco mode: ECO supply air, ECO extract air for passive summer night cooling. Complete separation of the extract air/supply air ducting throughout the entire appliance. This prevents unwanted air recirculation. Viruses (coronavirus) and bacteria are therefore not transmitted. Room air control RLS 1 WR included in the scope of delivery. The WS 120 Trio can be controlled via APP (air@home) and the browser-based web tool (##########_1__-##########_2__) using the integrated LAN interface. Plug & Play: Easy commissioning thanks to free commissioning software and standard USB connection for commissioning, control updates and servicing. USB interface integrated in the device cover - no need to remove the device cover for commissioning/software update. No pressure fluctuation sensitivity: The integrated / automatic constant volume flow control ensures that the set volume flow is maintained at all times under all operating conditions (filter contamination, air valve settings). This also results in simpler commissioning / air volume measurement at the valves. No adjustment of the volume flows is necessary. Combination sensor (humidity/temperature) integrated as standard in the exhaust air enables demand-led ventilation operation and an intelligent dehumidification strategy (overhumidification protection). The appliance is also characterised by a frost protection strategy that is adapted to actual requirements. The heat recovery unit has a multi-function contact for the control of z.B. Brine earth heat exchanger (uncontrolled pump), operating and fault display, preheating or reheating coil, external dampers or cooling. 2 input contacts (12 V and 230 V) are available for safety-related shutdowns. Various inputs/outputs enable a control connection to other building services devices z.B. heat pump. Integrated MODBUS interface (TCP/IP and RTU) for integration into the building management system. The optional K-SM plug-in module enables integration into KNX building systems. The optional E-SM plug-in module enables integration into EnOcean systems. Optional additional boards ZP 1 and ZP 2 for extension functions such as z.B. Zone damper, brine earth heat exchanger (controlled pump), filter differential pressure measurement. Maximum appliance flexibility thanks to a wide range of equipment/connection options. Modern modular appliance technology enables a high level of user-friendliness for service and maintenance. Housing: Housing made of black EPP with traffic-white sheet steel cover. Filter can be changed easily without tools. Tight, thermal bridge-free and sound-insulated inner housing. Device surface and inner housing are easy to clean. Filter: ISO ePM10 >= 50 % (M5) filter in the exhaust air and ISO ePM1 >= 50 % (F7) pollen filter in the outside air. Tool-free filter replacement. Operation: RLS 1 WR control panel included in the scope of delivery, 4 air stages, filter change indicator, fault indicator. Additional control panels can be connected in parallel. Mobile operation via APP (air@home) or browser-based web tool (##########_1__-##########_2__) via smartphone, laptop or PC enables ##########_0__. Live reporting, user management. Demand-controlled automatic operation / time-controlled automatic operation. Manual operation / OFF. ECO mode supply air or ECO mode extract air. Filter queries, error messages. Optional RLS T2 WS touchscreen control panel for setting: 2 automatic operating modes (Auto Sensor / Auto Time). 4 manual operating modes (ECO exhaust air / ECO supply air / MANUAL / OFF). Complete commissioning of the WS 120 Trio possible. USB connection for service / commissioning - free MAICO commissioning software. Network integration via integrated LAN interface. Smart-Home ready (z.B. Loxone via Modbus TCP/IP). Modbus TCP/IP and RTU integrated as standard. Optional KNX plug-in module K-SM for integration into building management systems ##########_12__.org. Optional EnOcean plug-in module E-SM for device integration into the EnOcean world www.enocean-allinace.org. Control: Demand-led volume flow control as standard (decisive humidity value). Stepless demand-led adjustment of the air volumes. Integrated over-humidity protection function. 3 temperature sensors in the outside, exhaust and supply air. 1 combination sensor (temperature and humidity) in the exhaust air spigot. Up to 4 external sensors of different types (CO2, VOC, humidity) can be connected. Multifunction contact for controlling z.B. Brine earth heat exchanger (uncontrolled pump), operating and fault display, preheating or reheating coil, external dampers or cooling. Inputs for safety-related switch-off via 12 V contact or 230 V contact (z.B. Smoke detector, fire alarm, differential-pressure-free fireplace). Additional push-button input for triggering time-limited intensive ventilation (shock ventilation). Can be extended via optional additional circuit board ZP 1 to control: 3-way damper (z.B. Air/earth heat exchanger). A controlled pump (z.B. Brine earth heat exchanger). An air damper of a zone control. Switch contact use for external reheating coil. Expandable via optional additional circuit board ZP 2 for: Constant pressure of the EC fans. Differential pressure-controlled filter monitoring. Various inputs and outputs enable a control connection of the ventilation unit with another building services device such as z.B. Heat pump. Approvals and certificates: Test report in accordance with DIN EN 13141-7. Hygiene certificates for casing material (EPP) and heat exchanger. DIBt approval has been applied for. Heat exchanger/heat recovery: Highly efficient enthalpy cross-counterflow heat exchanger. Heat recovery up to 81 % for the L variants and 84 % for the Q variants. Humidity recovery up to 69 %. Hygiene certificate (no bacteria, virus growth/virus transfer) in accordance with VDI 6022, Sheet 1. Heat exchanger can be cleaned with water, antimicrobial. No condensate connection necessary. Bypass: Eco mode: ECO supply air, ECO extract air for passive summer night cooling. Frost protection: Prevention of heat exchanger freezing at low temperatures by monitoring the exhaust air temperature. If there is a risk of frost, the fresh air volume flow is gradually reduced. V versions: Frost protection through integrated preheating coil. Fans: Forward curved centrifugal fans in the exhaust air or outside air. Energy-efficient EC DC motors with integrated constant volume flow control. Possibility of constant pressure control via the optional ZP 2 additional circuit board. 3 ventilation levels continuously adjustable from 40 m3/h to 120 m3/h. Installation instructions: Easy, very time-saving installation by screwing the device directly to the ceiling / wall. Housing cover can be easily removed using screws. The mains cable is fed approx. 2.5 m out of the appliance, the cable for connecting the RLS 1 WR control unit is fed approx. 2 m from the appliance ##########_20__: WS 120 Trio QL, Design: Cross-flow, exhaust air left, Delivery volume: 40 m3/h / 120 m3/h, Speed: 2200 1/min, Energy efficiency class: A, Voltage type: Alternating current, Rated voltage: 230 V, Mains frequency: 50 Hz / 60 Hz, SPI value according to DIN EN 13141-7 (A7): 0.27 Wh/m3, Power consumption according to DIN EN 13141-7 (A7): 20 W, Stand-by power consumption: < 1 W, IMax: 1 A, Protection rating: IP 40, DIBT approval: yes, Installation location: wall / ceiling, System type: central, Material: EPP plastic/ galvanised sheet steel, Housing material: EPP plastic, Heat exchanger material: plastic, Colour: black / silver, Weight: 25 kg, Weight with packaging: 28 kg, Filter class: ISO ePM10 >= 50 % (M5) / ISO ePM1 >= 50 % (F7), Connection diameter: 125 mm (outside air/exhaust air), 75 mm (supply air/exhaust air), Number of connection spigots: 10, Width: 600 mm, Height: 210 mm, Depth: 1000 mm, Width with packaging: 720 mm, Height with packaging: 300 mm, Depth with packaging: 1120 mm, Conveying medium temperature at IMax: -20 °C to 50 °C, Max. Heat recovery efficiency according to DIN EN 13141-7 (A7): 84 %, Heat exchanger type: enthalpy cross-counterflow, Bypass: no, Pre-heating coil: no, Enthalpy heat exchanger: yes, Frost protection circuit: yes, Summer circuit: ECO exhaust air / ECO supply air, Filter monitoring: time-controlled, Humidity control: integrated, CO2 control: CO2 sensor for Trio, Air quality control (optional): VOC sensor for Trio, KNX connection (optional): K-SM, MODBUS interface: integrated, Control panel included: RLS 1 WR, App, Control panel (optional): RLS T2 WS, RLS G1 WS, EnOcean radio integration (optional): E-SM, Mobile control: yes, Suitable for roof ventilators: no, Suitable for wall-mounted ventilators: no, Suitable for box ventilators: no, Suitable for circulation ventilators: no, Suitable for duct ventilators: no, Suitable for centrifugal ventilators: no, Suitable for wall-mounted ventilators: no, Suitable for domestic ventilators: no, Suitable for heat recovery systems: no

Regular price: €2,188.33
Maico Central Ventilation Unit WS 120 Trio QLV 0095.0660
Maico Central Ventilation Unit WS 120 Trio QLV 0095.0660

WS 120 Trio QLV - Brief InformationCross-flow compact and quiet central unit, exhaust air on the left, with effective heat and moisture recovery, EC fans with constant volume flow control, connection of a duct system, 40-120 m³/h, frost protection through integrated pre-heating coilWS 120 Trio QLV - Product DescriptionBrief DescriptionIntelligent ventilation unit with heat and moisture recovery for controlled supply and exhaust ventilation with a delivery volume of 40 to 120 m³/h.Compact and highly efficient - Energy efficiency class A. Sound and energy-optimised fans in EC technology.Eligible for KfW funding and NRW funding.Especially suitable for modern new builds or renovations.Very quiet unit with extremely low installation height (21 cm) and low weight (25 kg): Therefore particularly suitable for installation in suspended ceilings. Installation on the wall or roof slope is also possible.Outside, exhaust, supply and extract air connections in DN 125: Maximum flexibility through 3D air connections, duct connection possible on every side. The EPP plug simply needs to be repositioned for this.Additional flexibility on the supply and extract air side: Optional DN 125 connection or direct air guidance with up to four DN 75 air ducts each for supply and extract air. Simple and quick installation by breaking out or repositioning the EPP plugs.ISO ePM10 ≥ 50 % (M5) filter in the extract air and ISO ePM1 ≥ 60 % (F7) pollen filter in the outside air.Tool-free filter change.The ventilation unit is equipped with a state-of-the-art enthalpy heat exchanger with hygiene certificate according to VDI 6022, Sheet 1.Bypass operation / Eco mode: ECO supply air, ECO extract air for passive summer night cooling.Complete separation of extract/supply air flow throughout the unit. This prevents unwanted recirculation. Viruses (e.g. coronavirus) and bacteria are thus not transmitted.Room air control RLS 1 WR included in delivery.The WS 120 Trio can be controlled via APP (Maico@home).Plug & Play: Easy commissioning with free commissioning software and standard USB connection for commissioning, control update and service.USB interface integrated in the device cover – no need to remove the device cover during commissioning/software update.No sensitivity to pressure fluctuations: The integrated/automatic constant volume flow control ensures permanent compliance with the set volume flow under all operating conditions (e.g. filter contamination, air valve settings). This also results in easier commissioning/air volume measurement at the valves. No balancing of volume flows is necessary.Standard integrated combined sensor (humidity/temperature) in the extract air enables demand-controlled ventilation operation as well as an intelligent dehumidification strategy (over-humidity protection). Furthermore, the unit features a frost protection strategy adapted to the actual demand.The heat recovery unit has a multifunction contact for controlling e.g. brine-earth heat exchanger (unregulated pump), operating and fault indication, pre-heating or post-heating coil, outside flaps or cooling.2 input contacts (12 V and 230 V) are available for e.g. safety shutdowns.Various inputs/outputs allow control connection to other building services devices, e.g. heat pump.Integrated MODBUS interface (TCP/IP and RTU) for integration into building management systems.Integrated BACnet interface (TCP/IP) for integration into building management systems.Optional plug-in module K-SM enables integration into KNX building systems.Optional plug-in module E-SM enables integration into EnOcean systems.Optional additional circuit boards ZP 1 and ZP 2 for expansion functions such as zone damper, brine-earth heat exchanger (regulated pump), filter differential pressure measurement.Maximum device flexibility through various equipment/connection options.Modern device module technology enables high user-friendliness for service and maintenance.HousingHousing made of black EPP with traffic white steel sheet cover.Filter change possible without tools.Sealed, thermal bridge-free and sound-insulated inner housing.Device surface and inner housing are easy to clean.FiltersISO ePM10 ≥ 50 % (M5) filter in the extract air and ISO ePM1 ≥ 60 % (F7) pollen filter in the outside air.Tool-free filter replacement.OperationControl unit RLS 1 WR included, 4 air levels, filter change indicator, fault indicator.Additional control units can be connected in parallel.Mobile operation via APP (Maico@home).Live reporting, user management.Demand-controlled automatic operation / time-controlled automatic operation.Manual operation / OFF.ECO mode supply air or ECO mode extract air.Filter queries, error messages.Optional touchscreen control unit RLS T2 WS for setting:2 automatic operating modes (Auto Sensor / Auto Time).4 manual operating modes (ECO Extract / ECO Supply / MANUAL / OFF).Complete commissioning of the WS 120 Trio possible.Optional design control unit RLS G1 WS:ON/OFF5 levelsAutomatic operationECO supply air, ECO extract airFilter change and fault indicatorUSB connection for service / commissioning - free MAICO commissioning software.Network integration via integrated LAN interface.Smart-Home ready (e.g. Loxone via Modbus TCP/IP).Modbus TCP/IP and RTU integrated as standard.Optional KNX plug-in module K-SM for integration into building management systems www.knx.org.Optional EnOcean plug-in module E-SM for device integration into the "EnOcean world" www.enocean-allinace.org.ControlStandard demand-controlled volume flow control ("relevant humidity value").Stepless demand-controlled adjustment of air volumes.Integrated over-humidity protection function.3 temperature sensors in outside, exhaust and supply air.1 combined sensor (temperature and humidity) in the extract air connection.Up to 4 external sensors of various types (CO2, VOC, humidity) can be connected.Multifunction contact for controlling e.g. brine-earth heat exchanger (unregulated pump), operating and fault indication, pre-heating or post-heating coil, outside flaps or cooling.Inputs for safety shutdown via 12 V contact or 230 V contact (e.g. smoke detector, fire alarm, pressureless fireplace).Additional button input for triggering time-limited intensive ventilation (shock ventilation).Expandable via optional additional circuit board ZP 1 for controlling:3-way damper (e.g. air-earth heat exchanger).A regulated pump (e.g. brine-earth heat exchanger).An air damper of a zone control.Switch contact use for external post-heating coil.Expandable via optional additional circuit board ZP 2 for:Pressure constancy of EC fans.Differential pressure controlled filter monitoring.Various inputs and outputs allow control connection of the ventilation unit with another building services device such as a heat pump.Approvals and CertificatesTest report according to DIN EN 13141-7.Hygiene certificates for housing material (EPP) and heat exchanger.DIBt approval is applied for.Heat Exchanger/Heat RecoveryHighly efficient enthalpy cross-counterflow heat exchanger.Heat recovery up to 86 % for L variants and 91 % for Q variants.Moisture recovery up to 69 %.Hygiene certificate (no bacteria, virus growth/virus transmission) according to VDI 6022, Sheet 1.Heat exchanger washable with water, antimicrobial.No condensate connection necessary.Summer ModeEco mode: ECO supply air, ECO extract air for passive summer night cooling.Frost ProtectionPrevention of heat exchanger freezing at low temperatures by monitoring the exhaust air temperature.In case of frost risk, the outside air volume flow is gradually reduced.V versions: Frost protection through integrated pre-heating coil.FansForward curved radial fans in the exhaust and outside air.Energy-efficient EC direct current motors with integrated volume flow constancy control.Possibility of pressure constancy control via optional additional circuit board ZP 2.3 ventilation levels from 40 m³/h to 120 m³/h continuously adjustable.Installation InstructionsEasy, very time-saving installation by directly screwing the unit to the ceiling/wall.Housing cover easily removable via screws.The ventilation unit is delivered ready for connection.The mains connection cable (2.5 m) and the control cable (2 m) of the room air control RLS 1 WR are already wired in the ventilation unit at the factory.Installation / Operation / Maintenance Wiring diagramsCustomer service request/orderInstallation and operating instructions wibutler: pdf | onlineSafety instructions WS: pdf | onlineOperating instructions: pdf | onlineInstallation, commissioning and maintenance instructions: pdf | onlineQuick start operating instructions: pdf | online ArticleWS 120 Trio QLVVersionCross-flow, exhaust air left, integrated pre-heating coilDelivery volume40 m³/h - 120 m³/hSpeed2,200 1/minSEC average-38.03 kWh/(m²*a)Energy efficiency classAType of voltageAlternating currentRated voltage230 VMains frequency50 Hz / 60 HzSPI value according to DIN EN 13141-7 (A7)0.27 Wh/m³Power consumption according to DIN EN 13141-7 (A7)20 WStand-by power consumption< 1 WIMax5 AProtection classIP 00DIBt approvalapplied forInstallation locationWall / CeilingSystem typecentralMaterialPlastic EPP/ galvanized steel sheetHousing materialPlastic EPPHeat exchanger materialPlasticColourblack / traffic white (RAL 9016)Weight25 kgWeight with packaging28 kgFilter classISO ePM10 ≥ 50 % (M5) / ISO ePM1 ≥ 60 % (F7)Connection diameter125 mm (outside air / exhaust air / supply air / extract air), 75 mm (supply air / extract air)Width600 mmHeight210 mmDepth1,000 mmWidth with packaging720 mmHeight with packaging300 mmDepth with packaging1,120 mmMedium temperature at IMax-20 °C to 50 °CMax. heat supply rate according to DIN EN 13141-7 (A7)84 %Heat exchanger typeEnthalpy cross-counterflowMoisture recovery with enthalpy heat exchanger according to DIN EN 13141-7 (A2)69 %Extract air positionleftBypassnoPre-heating coilintegratedEnthalpy heat exchangeryesFrost protection circuityesSummer modeECO extract air / ECO supply airFilter monitoringtime-controlledHumidity controlintegratedCO2 control (optional)Trio CO2 E, Trio CO2 IAir quality control (optional)Trio VOC E, Trio VOC IKNX connection (optional)K-SMMODBUS interfaceintegratedControl unit includedRLS 1 WR, AppControl unit (optional)RLS T2 WS, RLS G1 WSRadio integration EnOcean (optional)E-SMMobile controlyesSound pressure level housing radiation30 dB / distance 1 m, sound absorption 10 m²Packaging unit1 pieceRangeKGTIN (EAN)4012799956600Article number0095.0660

Regular price: €2,370.93
Maico WS 120 Trio QR central ventilation unit 0095.0661
Maico WS 120 Trio QR central ventilation unit 0095.0661

Brief description: Intelligent ventilation unit with heat and moisture recovery for controlled ventilation with a flow rate of 40 to 120 m3/h. Compact, highly efficient - energy efficiency class A. Compact and highly efficient - energy efficiency class A. Sound and energy-optimised fans in EC technology. KFW subsidisable: Particularly suitable for modern new builds or refurbishments. Very quiet device with extremely low installation height (21 cm) and low weight (25 kg): This makes it particularly suitable for installation in suspended ceilings. Installation on the wall or sloping roof is also possible. External, exhaust, supply and return air spigots in DN 125: Maximum flexibility thanks to 3D air spigots, air duct connection possible on any side. The EPP plug simply needs to be repositioned. Additional flexibility on the supply and return air side: Choice of DN 125 connection or direct air routing with up to four DN 75 air ducts each for supply and return air. Quick and easy installation by breaking out or repositioning the EPP plugs. ISO ePM10 >= 50 % (M5) filter in the extract air and ISO ePM1 >= 50 % (F7) pollen filter in the outside air. Tool-free filter change. The ventilation unit is equipped with a state-of-the-art enthalpy heat exchanger with hygiene certificate in accordance with VDI 6022, Sheet 1. Bypass mode / eco mode: ECO supply air, ECO extract air for passive summer night cooling. Complete separation of the extract air/supply air ducting throughout the entire appliance. This prevents unwanted air recirculation. Viruses (coronavirus) and bacteria are therefore not transmitted. Room air control RLS 1 WR included in the scope of delivery. The WS 120 Trio can be controlled via APP (air@home) and the browser-based web tool (##########_1__-##########_2__) using the integrated LAN interface. Plug & Play: Easy commissioning thanks to free commissioning software and standard USB connection for commissioning, control updates and servicing. USB interface integrated in the device cover - no need to remove the device cover for commissioning/software update. No sensitivity to pressure fluctuations: The integrated / automatic constant volume flow control ensures that the set volume flow is maintained at all times under all operating conditions (filter contamination, air valve settings). This also results in simpler commissioning / air volume measurement at the valves. No adjustment of the volume flows is necessary. Combination sensor (humidity/temperature) integrated as standard in the exhaust air enables demand-led ventilation operation and an intelligent dehumidification strategy (overhumidification protection). The appliance is also characterised by a frost protection strategy that is adapted to actual requirements. The heat recovery unit has a multi-function contact for the control of z.B. Brine earth heat exchanger (uncontrolled pump), operating and fault display, preheating or reheating coil, external dampers or cooling. 2 input contacts (12 V and 230 V) are available for safety-related shutdowns. Various inputs/outputs enable a control connection to other building services devices z.B. heat pump. Integrated MODBUS interface (TCP/IP and RTU) for integration into the building management system. The optional K-SM plug-in module enables integration into KNX building systems. The optional E-SM plug-in module enables integration into EnOcean systems. Optional additional boards ZP 1 and ZP 2 for extension functions such as z.B. Zone damper, brine earth heat exchanger (controlled pump), filter differential pressure measurement. Maximum appliance flexibility thanks to a wide range of equipment/connection options. Modern modular appliance technology enables a high level of user-friendliness for service and maintenance. Housing: Housing made of black EPP with traffic-white sheet steel cover. Filter can be changed easily without tools. Tight, thermal bridge-free and sound-insulated inner housing. Device surface and inner housing are easy to clean. Filter: ISO ePM10 >= 50 % (M5) filter in the exhaust air and ISO ePM1 >= 50 % (F7) pollen filter in the outside air. Tool-free filter replacement. Operation: RLS 1 WR control panel included in the scope of delivery, 4 air stages, filter change indicator, fault indicator. Additional control panels can be connected in parallel. Mobile operation via APP (air@home) or browser-based web tool (##########_1__-##########_2__) via smartphone, laptop or PC enables ##########_0__. Live reporting, user management. Demand-controlled automatic operation / time-controlled automatic operation. Manual operation / OFF. ECO mode supply air or ECO mode extract air. Filter queries, error messages. Optional RLS T2 WS touchscreen control panel for setting: 2 automatic operating modes (Auto Sensor / Auto Time). 4 manual operating modes (ECO exhaust air / ECO supply air / MANUAL / OFF). Complete commissioning of the WS 120 Trio possible. USB connection for service / commissioning - free MAICO commissioning software. Network integration via integrated LAN interface. Smart-Home ready (z.B. Loxone via Modbus TCP/IP). Modbus TCP/IP and RTU integrated as standard. Optional KNX plug-in module K-SM for integration into building management systems ##########_12__.org. Optional EnOcean plug-in module E-SM for device integration into the EnOcean world www.enocean-allinace.org. Control: Demand-led volume flow control as standard (decisive humidity value). Stepless demand-led adjustment of the air volumes. Integrated over-humidity protection function. 3 temperature sensors in the outside, exhaust and supply air. 1 combination sensor (temperature and humidity) in the exhaust air spigot. Up to 4 external sensors of different types (CO2, VOC, humidity) can be connected. Multifunction contact for controlling z.B. Brine earth heat exchanger (uncontrolled pump), operating and fault display, preheating or reheating coil, external dampers or cooling. Inputs for safety-related switch-off via 12 V contact or 230 V contact (z.B. Smoke detector, fire alarm, differential-pressure-free fireplace). Additional push-button input for triggering time-limited intensive ventilation (shock ventilation). Can be extended via optional additional circuit board ZP 1 to control: 3-way damper (z.B. Air/earth heat exchanger). A controlled pump (z.B. Brine earth heat exchanger). An air damper of a zone control. Switch contact use for external reheating coil. Expandable via optional additional circuit board ZP 2 for: Constant pressure of the EC fans. Differential pressure-controlled filter monitoring. Various inputs and outputs enable a control connection of the ventilation unit with another building services device such as z.B. Heat pump. Approvals and certificates: Test report in accordance with DIN EN 13141-7. Hygiene certificates for casing material (EPP) and heat exchanger. DIBt approval has been applied for. Heat exchanger/heat recovery: Highly efficient enthalpy cross-counterflow heat exchanger. Heat recovery up to 81 % for the L variants and 84 % for the Q variants. Humidity recovery up to 69 %. Hygiene certificate (no bacteria, virus growth/virus transfer) in accordance with VDI 6022, Sheet 1. Heat exchanger can be cleaned with water, antimicrobial. No condensate connection necessary. Bypass: Eco mode: ECO supply air, ECO extract air for passive summer night cooling. Frost protection: Prevention of heat exchanger freezing at low temperatures by monitoring the exhaust air temperature. If there is a risk of frost, the fresh air volume flow is gradually reduced. V versions: Frost protection through integrated preheating coil. Fans: Forward curved centrifugal fans in the exhaust air or outside air. Energy-efficient EC DC motors with integrated constant volume flow control. Possibility of constant pressure control via the optional ZP 2 additional circuit board. 3 ventilation levels continuously adjustable from 40 m3/h to 120 m3/h. Installation instructions: Easy, very time-saving installation by screwing the device directly to the ceiling / wall. Housing cover can be easily removed using screws. The mains cable is fed approx. 2.5 m out of the appliance, the cable for connecting the RLS 1 WR control unit is fed approx. 2 m from the appliance ##########_20__: WS 120 Trio QR, Design: Cross-flow, exhaust air right, Delivery volume: 40 m3/h / 120 m3/h, Speed: 2200 1/min, Energy efficiency class: A, Voltage type: Alternating current, Rated voltage: 230 V, Mains frequency: 50 Hz / 60 Hz, SPI value according to DIN EN 13141-7 (A7): 0.27 Wh/m3, Power consumption according to DIN EN 13141-7 (A7): 20 W, Stand-by power consumption: < 1 W, IMax: 1 A, Protection rating: IP 40, DIBT approval: yes, Installation location: wall / ceiling, System type: central, Material: EPP plastic/ galvanised sheet steel, Housing material: EPP plastic, Heat exchanger material: plastic, Colour: black / silver, Weight: 25 kg, Weight with packaging: 28 kg, Filter class: ISO ePM10 >= 50 % (M5) / ISO ePM1 >= 50 % (F7), Connection diameter: 125 mm (outside air/exhaust air), 75 mm (supply air/exhaust air), Number of connection spigots: 10, Width: 600 mm, Height: 210 mm, Depth: 1000 mm, Width with packaging: 720 mm, Height with packaging: 300 mm, Depth with packaging: 1120 mm, Conveying medium temperature at IMax: -20 °C to 50 °C, Max. Heat recovery efficiency to DIN EN 13141-7 (A7): 84 %, Heat exchanger type: enthalpy cross-counterflow, Bypass: no, Pre-heating coil: no, Enthalpy heat exchanger: yes, Frost protection circuit: yes, Summer circuit: ECO exhaust air / ECO supply air, Filter monitoring: time-controlled, Humidity control: integrated, CO2 control: CO2 sensor for Trio, Air quality control (optional): VOC sensor for Trio, KNX connection (optional): K-SM, MODBUS interface: integrated, Control panel included: RLS 1 WR, App, Control panel (optional): RLS T2 WS, RLS G1 WS, EnOcean radio integration (optional): E-SM, Mobile control: yes, Suitable for roof ventilators: no, Suitable for wall-mounted ventilators: no, Suitable for box ventilators: no, Suitable for circulation ventilators: no, Suitable for duct ventilators: no, Suitable for centrifugal ventilators: no, Suitable for wall-mounted ventilators: no, Suitable for domestic ventilators: no, Suitable for heat recovery systems: no

Regular price: €2,188.33
Maico Central Ventilation Unit WS 120 Trio QRV 0095.0662
Maico Central Ventilation Unit WS 120 Trio QRV 0095.0662

WS 120 Trio QRV - Brief InformationCross-flow compact and quiet central unit, exhaust air on the right, with effective heat and moisture recovery, EC fans with constant volume flow control, connection of a duct system, 40-120 m³/h, frost protection through integrated pre-heating coilWS 120 Trio QRV - Product DescriptionBrief DescriptionIntelligent ventilation unit with heat and moisture recovery for controlled supply and exhaust ventilation with a delivery volume of 40 to 120 m³/h.Compact and highly efficient - Energy efficiency class A. Sound and energy-optimised fans in EC technology.KfW funding eligibility and NRW funding are available.Especially suitable for modern new builds or renovations.Very quiet unit with extremely low installation height (21 cm) and low weight (25 kg): Therefore particularly suitable for installation in suspended ceilings. Installation on the wall or roof slope is also possible.Outside, exhaust, supply and extract air connections in DN 125: Maximum flexibility through 3D air connections, duct connection possible on every side. For this, the EPP plug only needs to be repositioned.Additional flexibility on the supply and extract air side: Optional DN 125 connection or direct air guidance with up to four DN 75 air ducts each for supply and extract air. Simple and quick installation by breaking out or repositioning the EPP plugs.ISO ePM10 ≥ 50 % (M5) filter in the extract air and ISO ePM1 ≥ 60 % (F7) pollen filter in the outside air.Tool-free filter change.The ventilation unit is equipped with a state-of-the-art enthalpy heat exchanger with hygiene certificate according to VDI 6022, Sheet 1.Bypass operation / Eco mode: ECO supply air, ECO extract air for passive summer night cooling.Complete separation of extract/supply air flow throughout the unit. This prevents unwanted recirculation. Viruses (e.g. coronavirus) and bacteria are thus not transmitted.Room air control RLS 1 WR included in delivery.The WS 120 Trio can be controlled via APP (Maico@home).Plug & Play: Easy commissioning through free commissioning software and standard USB connection for commissioning, control update and service.USB interface integrated in the device cover – no need to remove the device cover during commissioning/software update.No sensitivity to pressure fluctuations: The integrated/automatic constant volume flow control ensures permanent compliance with the set volume flow under all operating conditions (e.g. filter contamination, air valve settings). This also results in easier commissioning/air volume balancing at the valves. No volume flow adjustment is necessary.Standard integrated combined sensor (humidity/temperature) in the extract air enables demand-controlled ventilation operation as well as an intelligent dehumidification strategy (over-humidity protection). Furthermore, the unit features a frost protection strategy adapted to actual demand.The heat recovery unit has a multifunction contact for controlling e.g. brine-earth heat exchanger (unregulated pump), operating and fault indication, pre-heating or post-heating coil, outside flaps or cooling.2 input contacts (12 V and 230 V) are available for e.g. safety shutdowns.Various inputs/outputs allow control connection to other building technology devices, e.g. heat pump.Integrated MODBUS interface (TCP/IP and RTU) for integration into building management systems.Integrated BACnet interface (TCP/IP) for integration into building management systems.Optional plug-in module K-SM enables integration into KNX building systems.Optional plug-in module E-SM enables integration into EnOcean systems.Optional additional circuit boards ZP 1 and ZP 2 for expansion functions such as zone damper, brine-earth heat exchanger (regulated pump), filter differential pressure measurement.Maximum device flexibility through various equipment/connection options.Modern device module technology enables high user-friendliness for service and maintenance.HousingHousing made of black EPP with traffic white steel sheet cover.Filter change possible without tools.Sealed, thermal bridge-free and sound-insulated inner housing.Device surface and inner housing are easy to clean.FiltersISO ePM10 ≥ 50 % (M5) filter in the extract air and ISO ePM1 ≥ 60 % (F7) pollen filter in the outside air.Tool-free filter replacement.OperationControl unit RLS 1 WR included, 4 air levels, filter change indicator, fault indicator.Additional control units can be connected in parallel.Mobile operation via APP (Maico@home).Live reporting, user management.Demand-controlled automatic operation / time-controlled automatic operation.Manual operation / OFF.ECO mode supply air or ECO mode extract air.Filter queries, error messages.Optional touchscreen control unit RLS T2 WS for setting:2 automatic operating modes (Auto Sensor / Auto Time).4 manual operating modes (ECO Extract / ECO Supply / MANUAL / OFF).Complete commissioning of the WS 120 Trio possible.Optional design control unit RLS G1 WS:ON/OFF5 levelsAutomatic operationECO supply air, ECO extract airFilter change and fault indicatorUSB connection for service / commissioning - free MAICO commissioning software.Network integration via integrated LAN interface.Smart-Home ready (e.g. Loxone via Modbus TCP/IP).Modbus TCP/IP and RTU integrated as standard.Optional KNX plug-in module K-SM for integration into building management www.knx.org.Optional EnOcean plug-in module E-SM for device integration into the “EnOcean world” www.enocean-allinace.org.ControlStandard demand-controlled volume flow control (“relevant humidity value”).Stepless demand-controlled adjustment of air volumes.Integrated over-humidity protection function.3 temperature sensors in outside, exhaust and supply air.1 combined sensor (temperature and humidity) in the extract air connection.Up to 4 external sensors of various types (CO2, VOC, humidity) can be connected.Multifunction contact for controlling e.g. brine-earth heat exchanger (unregulated pump), operating and fault indication, pre-heating or post-heating coil, outside flaps or cooling.Inputs for safety shutdown via 12 V contact or 230 V contact (e.g. smoke detector, fire alarm, pressureless fireplace).Additional push-button input for triggering time-limited intensive ventilation (shock ventilation).Expandable via optional additional circuit board ZP 1 for controlling:3-way damper (e.g. air-earth heat exchanger).A regulated pump (e.g. brine-earth heat exchanger).An air damper of a zone control.Switch contact use for external post-heating coil.Expandable via optional additional circuit board ZP 2 for:Pressure constancy of EC fans.Differential pressure-controlled filter monitoring.Various inputs and outputs allow control connection of the ventilation unit with another building technology device such as a heat pump.Approvals and CertificatesTest report according to DIN EN 13141-7.Hygiene certificates for housing material (EPP) and heat exchanger.DIBt approval has been applied for.Heat Exchanger/Heat RecoveryHighly efficient enthalpy cross-counterflow heat exchanger.Heat recovery up to 86 % for L variants and 91 % for Q variants.Moisture recovery up to 69 %.Hygiene certificate (no bacteria, virus growth/virus transmission) according to VDI 6022, Sheet 1.Heat exchanger washable with water, antimicrobial.No condensate connection necessary.Summer ModeEco mode: ECO supply air, ECO extract air for passive summer night cooling.Frost ProtectionPrevention of heat exchanger freezing at low temperatures by monitoring the exhaust air temperature.In case of frost risk, the outside air volume flow is gradually reduced.V versions: Frost protection through integrated pre-heating coil.FansForward-curved radial fans in the exhaust and outside air.Energy-efficient EC direct current motors with integrated volume flow constancy control.Possibility of pressure constancy control via optional additional circuit board ZP 2.3 ventilation levels from 40 m³/h to 120 m³/h continuously adjustable.Installation InstructionsEasy, very time-saving installation by directly screwing the unit to the ceiling/wall.Device cover easily removable via screws.The ventilation unit is delivered ready for connection.The mains connection cable (2.5 m) and the control cable (2 m) of the room air control RLS 1 WR are already wired in the ventilation unit at the factory.Installation / Operation / Maintenance Wiring diagramsCustomer service request/orderInstallation and operating instructions wibutler: pdf | onlineSafety instructions WS: pdf | onlineOperating instructions: pdf | onlineInstallation, commissioning and maintenance instructions: pdf | onlineQuick start operating instructions: pdf | online ArticleWS 120 Trio QRVVersionCross-flow, exhaust air right, integrated pre-heating coilDelivery volume40 m³/h - 120 m³/hSpeed2,200 1/minSEC average-38.03 kWh/(m²*a)Energy efficiency classAType of voltageAlternating currentRated voltage230 VMains frequency50 Hz / 60 HzSPI value according to DIN EN 13141-7 (A7)0.27 Wh/m³Power consumption according to DIN EN 13141-7 (A7)20 WStand-by power consumption< 1 WIMax5 AProtection classIP 00DIBt approvalapplied forInstallation locationWall / CeilingSystem typecentralMaterialPlastic EPP/ galvanized steel sheetHousing materialPlastic EPPHeat exchanger materialPlasticColourblack / traffic white (RAL 9016)Weight25 kgWeight with packaging28 kgFilter classISO ePM10 ≥ 50 % (M5) / ISO ePM1 ≥ 60 % (F7)Connection diameter125 mm (outside air / exhaust air / supply air / extract air), 75 mm (supply air / extract air)Width600 mmHeight210 mmDepth1,000 mmWidth with packaging720 mmHeight with packaging300 mmDepth with packaging1,120 mmTransport medium temperature at IMax-20 °C to 50 °CMax. heat supply rate according to DIN EN 13141-7 (A7)84 %Heat exchanger typeEnthalpy cross-counterflowMoisture recovery with enthalpy heat exchanger according to DIN EN 13141-7 (A2)69 %Extract air positionrightBypassnoPre-heating coilintegratedEnthalpy heat exchangeryesFrost protection circuityesSummer modeECO extract air / ECO supply airFilter monitoringtime-controlledHumidity controlintegratedCO2 control (optional)Trio CO2 E, Trio CO2 IAir quality control (optional)Trio VOC E, Trio VOC IKNX connection (optional)K-SMMODBUS interfaceintegratedControl unit includedRLS 1 WR, AppControl unit (optional)RLS T2 WS, RLS G1 WSRadio integration EnOcean (optional)E-SMMobile controlyesSound pressure level housing radiation30 dB / distance 1 m, sound absorption 10 m²Packaging unit1 pieceRangeKGTIN (EAN)4012799956624Article number0095.0662

Regular price: €2,370.93